Knowledge Base › Tolerance and Fit Error Case › Welding Positioner Turntable Flatness Error

Welding Positioner Turntable Flatness Error

E43-380 · Welded/Cast Forming Dimensional Error · A positioner turntable ø1000mm, designed flatness 0.03, measured post-weld 0.14 · ★★

Problem Description

Fabrication-weld distortion of the turntable pushes flatness 0.14mm out of tolerance and tilts the workholding.

Root Cause

[Mechanism] Plate-up welding shrinkage warps the turntable, leaving the face off the theoretical plane.
[Calculation] Flatness w≈σ·D²/(16Eh)=25×1000²/(16×110000×40)≈0.035 (0.14mm measured), 4.7× the tolerance of 0.03.
[Design Omission] No post-weld finish turning or aging — a design defect leading to flatness error.

Corrective Solution

1) Age after welding to relieve stress;
2) Finish-turn the turntable face to hold flatness;
3) Weld symmetrically in segments;
4) Provide a process datum;
5) Control heat input;
6) Check by scraping with a straight edge;
7) Align the center;
8) Measure first-article flatness ≤0.03mm.

Checklist

Reference

GB/T 11337-2004 Flatness tolerances