E43-389 · Welded/Cast Forming Dimensional Error · A column 2000mm tall, designed guideway twist ≤0.02, measured post-cast 0.12 · ★★★
Casting twist of the column pushes guideway twist 0.12mm out of tolerance, seizing the moving carriage.
[Mechanism] Uneven cooling of the column section induces torsion, twisting the guideway face off alignment.
[Calculation] Twist angle γ≈Δ/L=0.12/2000≈0.00006 rad, 2× the tolerance corresponding to 0.02/2000.
[Design Omission] No symmetric rib layout or aging — a design defect leading to guideway twist error.
1) Lay out ribs symmetrically in the column to reduce twist;
2) Long-age after casting;
3) Finish-machine the guideway face;
4) Second aging between roughing and finishing;
5) Low-stress fixturing;
6) Check by scraping with a straight edge;
7) Provide a process datum;
8) Measure first-article twist ≤0.02mm.
GB/T 11337-2004 Flatness tolerances