E43-390 · Welded/Cast Forming Dimensional Error · A vessel manhole flange ø500, designed misalignment ≤1, measured circumferential weld 3 · ★★
Circumferential weld misalignment of the manhole flange is 3mm, leaving a large inner-wall step and stress concentration.
[Mechanism] Fit-up misalignment of the manhole flange to the shell leaves an inner-wall step out of tolerance after circumferential welding.
[Calculation] Misalignment e=3mm, 3× the tolerance of 1; the step raises local stress by 40%.
[Design Omission] No fit-up fixture to control concentricity — a design defect leading to misalignment error.
1) Use a fit-up fixture to control concentricity;
2) Position with an internal expansion ring to prevent misalignment;
3) Check misalignment ≤1 before tacking;
4) Weld symmetrically to prevent shift;
5) Grind the inner face to level the step;
6) Control the gap;
7) Check misalignment with a weld gauge;
8) Measure first-article misalignment ≤1mm.
GB/T 150.4-2011 Pressure vessels - Part 4: Fabrication