Welded Slewing-Bearing Mounting Flatness Out of Tolerance

E43-399 · Welding and Casting Dimensional Error · A ø1200mm slewing-bearing mount whose design flatness of 0.03 measured 0.16 after welding · ★★

Problem Description

Assembly-welding distortion of the mount left the mounting face 0.16mm out of flat, causing uneven slewing clearance.

Root Cause

[Mechanism] Weld-shrinkage warpage of the fabricated mount pulls the mounting face away from its theoretical plane.
[Calculation] Flatness w≈σ·D²/(16Eh)=25×1200²/(16×110000×50)≈0.04 (compounding with the measured 0.16), 5.3 times the 0.03mm tolerance.
[Design Omission] No post-weld finish turning or aging — a design defect leading to flatness error.

Corrective Solution

1) Age the whole assembly after welding;
2) Finish-turn the mounting face to hold flatness;
3) Weld symmetrically in segments;
4) Provide a process datum;
5) Control heat input;
6) Check by scraping with a straight edge;
7) Align the center;
8) Measure first-article flatness ≤0.03mm.

Checklist

Reference

GB/T 11337-2004 Flatness tolerances