E46-020 · Welding Process & Distortion · Thick-Plate Butt Joint · ★★★

Problem Description

A 40mm thick plate was welded without preheat, and the heat-affected zone cold-cracked and leaked

Root Cause

[Mechanism] Without preheat a thick plate cools fast and hardens, causing hydrogen-induced cold cracking.
[Calculation] Without preheat the cooling rate exceeds the critical value, cracking the hardened layer.
[Design gap] No preheat was applied.

Corrective Solution

① Preheat by thickness: preheat a 40mm thick plate to no less than 100℃ before welding, then cool slowly
② Measure the preheat temperature: measure the preheat temperature to ensure it meets the requirement and is sufficient
③ Low-hydrogen filler: use low-hydrogen filler metal to reduce the hydrogen content
④ Slow cooling after welding: cool slowly after welding to avoid cold cracking
⑤ NDT for cold cracks: inspect for cold cracks by NDT and correct them early
⑥ Control interpass temperature: control the interpass temperature to stabilize quality
⑦ Crack-prevention verification: confirm there are no cold cracks by NDT
⑧ Standardize process: write the preheat requirement into the welding procedure specification (WPS), controlling at the source

Checklist

Reference

GB/T 19866-2005 General principles for welding procedure specification and qualification