Uncleared Interpass Slag Causes Slag Inclusion

E46-035 · Welding Process & Distortion · Multi-Pass Welding · ★★

Problem Description

Uncleared interpass slag left slag inclusions that weakened the section and caused cracking and leakage

Root Cause

[Mechanism] Uncleared interpass slag is rolled into the new pass, forming slag inclusions that weaken the joint.
[Calculation] An excessive slag-inclusion rate reduces the effective section, causing cracking and leakage under load.
[Design gap] Interpass slag was not cleaned.

Corrective Solution

① Clean slag after every pass: remove slag after each pass of a multi-pass weld to keep the interpass zone clean
② Slag-cleaning tools: clean with a slag hammer and wire brush to keep the surface clean
③ Radiographic slag inspection: use RT to check for slag inclusions and detect them early
④ Repair slag inclusions: repair the slag-inclusion locations to restore the section
⑤ Qualification check: verify interpass cleanliness with a test plate to ensure quality
⑥ In-process inspection: check for slag and correct early
⑦ Slag-inclusion verification: confirm the slag inclusions have been eliminated by RT
⑧ Standardize process: write the slag-removal requirement into the welding procedure specification (WPS), controlling at the source

Checklist

Reference

GB/T 3323-2005 Radiographic examination of fusion-welded joints in metals