MOULDLKnowledge Base3D Model DownloadsMembership
中文版Model Store »
HomeModels
Table of contents

Knowledge Base Home

📐 Standard Data

🧮 Calculators

📖 Selection Guides

🏭 Material Grades

❓ Engineer FAQ

🗂 Quick-Reference Categories

❌ Error Case Studies

📚 Technical Articles

Knowledge Base › Process and Assembly Error Case Study › Missing Cold Treatment Changes Dimensions

Missing Cold Treatment Changes Dimensions

E46-064 · Heat Treatment & Stress · Cr12 Gauge Block · ★★

Problem Description

A Cr12 gauge block was quenched and tempered without cold treatment; after one month in storage it grew 0.02mm, exceeding the 0.005mm tolerance, and failed calibration.

Root Cause

[Mechanism] Without cold treatment the retained austenite later transforms to martensite, causing continuous dimensional change.
[Calculation] Transformation of about 8% retained austenite changes the gauge-block dimensions by four times the tolerance.
[Design gap] No cold-treatment step was specified for high-precision gauges.

Corrective Solution

① Add cold treatment: cold-treat at -70~-80℃ for 2~3h promptly after quenching to transform the retained austenite
② Matching tempering: temper at low temperature after cold treatment to stabilize the structure
③ Aging stabilization: after treatment let the part rest for several days so the dimensions fully stabilize before finish grinding
④ Multiple cycles: for ultra-high-precision parts use repeated cold-treatment and tempering cycles
⑤ Dimension tracking: track and measure the change of key dimensions over the long term
⑥ Hardness confirmation: measure the hardness after treatment to confirm the transformation is complete
⑦ Dimension verification: confirm stable acceptance by long-term dimension tracking
⑧ Standardize process: write cold treatment into the process for high-precision gauges, controlling at the source

Checklist

Reference

GB/T 1299-2014 Tool and die steels

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL