E46-111 · Assembly Sequence & Datum · Bearing and Shaft · ★★
For the interference fit between the bearing inner ring and the shaft, the shaft was mistakenly heated to 150℃ to slip on the bearing; after cooling the shaft contracted, the bearing came loose and slipped in operation.
[Mechanism] An interference fit should be achieved by heating the bore or chilling the shaft; heating the shaft actually removes the interference.
[Calculation] The shaft's thermal expansion reduces the interference to zero, and after cooling it becomes a clearance fit.
[Design gap] The direction of the temperature-difference method - heating the inner ring or chilling the shaft - was not specified.
① Heat the inner ring: heat the bearing inner ring to 80~100℃ and slip it onto the room-temperature shaft using thermal expansion
② Or chill the shaft: cool the shaft to -50~-80℃ with liquid nitrogen and fit it into the room-temperature bearing using contraction
③ Control the temperature: keep the heating temperature below the bearing tempering temperature, usually 120℃, to prevent annealing
④ Measure the interference: before assembly measure the shaft journal and inner ring bore to confirm the interference is 0.01~0.04mm
⑤ Assemble quickly: after heating, slip it on and push it home promptly to avoid it jamming partway as it cools
⑥ In-process inspection: after assembly check that the bearing turns freely with no axial play
⑦ Quality verification: confirm the interference is reliable by the push-in force or torque
⑧ Standardize process: write the direction of the temperature-difference method into the work instruction, controlling at the source
GB/T 5371-2004 Limits and fits - Calculation and selection of interference fits