E46-116 · Assembly Sequence & Datum · Stud Joint · ★★
The nut was threaded onto the stud before the stud was turned into the housing; the threaded-in end of the stud did not seat to depth in the housing and the joint loosened.
[Mechanism] A stud should first be turned into the housing to the specified depth without the nut, and the nut fitted afterward; the reversed order leaves the engagement short.
[Calculation] Insufficient thread engagement reduces the load capacity and the joint loosens.
[Design gap] Turning the stud into the housing before fitting the nut was not specified.
① Turn into the body first: first turn the stud into the threaded hole of the housing to the specified engagement depth, e.g. 1.5d
② Use a wrench surface: tighten using the unthreaded portion of the stud or a dedicated wrench, not the nut
③ Control the depth: after turning in, check with a depth gauge and confirm the design requirement is met
④ Fit the nut afterward: once the stud is seated, fit the nut on the plain end and tighten to the specified torque
⑤ Locking treatment: add a locking washer or thread-locking compound to the nut as designed
⑥ In-process inspection: check the engagement depth and detect any shortfall early
⑦ Quality verification: confirm the joint is reliable with a torque wrench
⑧ Standardize process: write the stud assembly sequence into the work instruction, controlling at the source
GB/T 3098.1-2010 Mechanical properties of fasteners