E46-119 · Assembly Sequence & Datum · Flange Joint · ★★
The eight flange bolts were tightened one after another around the circumference; the flange face twisted by 0.4mm and the gasket was crushed locally, causing leakage.
[Mechanism] Tightening in circumferential order twists and displaces the flange, loading the sealing face unevenly.
[Calculation] The 0.4mm twist exceeds the requirement for uniform gasket compression, causing local leakage.
[Design gap] Crosswise symmetrical stepwise tightening was not adopted.
① Crosswise symmetrical: tighten in a crosswise diagonal order in 3 increasing passes
② Stepwise force: tighten to 30% torque the first time, 60% the second and 100% the third, applying force evenly
③ Control the torque: tighten to the design value with a calibrated torque wrench and record every bolt
④ Check the gap: after each pass check with a feeler gauge that the flange gap is even, confirming a difference ≤0.05mm
⑤ Clean the seal: before assembly clean the sealing face and gasket with no damage
⑥ In-process inspection: monitor the flange gap during tightening to detect twisting early
⑦ Quality verification: confirm there is no leakage by a hydraulic pressure test
⑧ Standardize process: write symmetrical stepwise tightening into the assembly card, controlling at the source
GB/T 3098.1-2010 Mechanical properties of fasteners