E46-138 · Assembly Sequence & Datum · Long Shaft Support · ★★★
Both bearing housings at the ends of a long shaft were rigidly fixed; when the temperature rose the shaft elongated by 0.8mm with nowhere to go, and the bearings seized.
[Mechanism] A long shaft should be fixed at one end and free to float at the other; leaving no thermal expansion clearance traps the shaft.
[Calculation] The temperature rise elongates the shaft by 0.8mm, exceeding the bearing clearance, so it seizes.
[Design gap] A floating support at one end was not specified.
① Float one end: fix the bearing at one end of the long shaft and leave axial float clearance in the housing at the other end
② Provide clearance: calculate the shaft elongation from the temperature rise and reserve at the floating end at least the elongation plus a margin
③ Select the bearing: use a bearing whose outer ring can move axially at the floating end, such as an NU type
④ Control the temperature rise: keep the operating temperature rise within the design range to reduce elongation
⑤ Re-measure the axial clearance: after assembly measure the clearance at the floating end to confirm it is sufficient
⑥ In-process inspection: during assembly confirm the floating end has not been wrongly fixed
⑦ Quality verification: confirm by a heat-up trial run that the shaft expands freely without sticking
⑧ Standardize process: write fixed-at-one-end, floating-at-the-other into the assembly process, controlling at the source
GB/T 307.3-2017 Rolling bearings — General technical specifications