E46-145 · Assembly Sequence & Datum · Angular Contact Bearing Set · ★★
For the angular contact bearing pair, the inner ring was pressed on first and the outer ring then shrink-fitted hot; after the outer ring cooled it was not coaxial with the inner ring and the preload failed.
[Mechanism] The set should be heated as a whole or assembled by the specified temperature-difference method; fitting the inner ring before the outer lets the relative position of the two rings get out of control.
[Calculation] Misalignment of the outer ring loads the preload spacer unevenly, giving abnormal clearance.
[Design gap] The assembly sequence for the bearing pair and the match-grinding of the spacer were not specified.
① Assemble as a pair: assemble the angular contact bearings as a pair, either tandem or back-to-back as required
② Match the spacer: match-grind the spacer to the mated dimensions of the two bearings to control the preload
③ Temperature-difference method: heat the outer ring or chill the shaft for fitting, avoiding forced pressing that causes misalignment
④ Control the preload: after assembly measure the preload or clearance to confirm the design value
⑤ Re-check coaxiality: after assembly measure the coaxiality and rotation of the two rings to confirm free running
⑥ In-process inspection: check the spacer during assembly to find errors early
⑦ Quality verification: confirm the preload is suitable by the temperature rise and noise
⑧ Standardize process: write the paired-bearing assembly sequence into the work instruction, controlling at the source
GB/T 307.3-2017 Rolling bearings — General technical specifications