E46-160 · Fastening & Anti-Loosening · Construction machinery outrigger · ★★★
The outrigger cylinder hinge of construction machinery used ordinary hexagon nuts; after long-term impact vibration the nuts loosened, the pin clearance grew and the outrigger sank and lost stability, creating a risk of the machine tipping over.
[Mechanism] An ordinary nut relies only on thread friction for anti-loosening; under impact vibration the fluctuation of the friction coefficient overcomes the anti-loosening torque and it loosens.
[Calculation] Vibration impact acceleration makes the tangential force on the thread pair momentarily exceed the frictional anti-loosening force, and the loosening angular rate accumulates with the number of impacts.
[Design gap] Anti-loosening fasteners were not selected for hinge points under impact load.
① Switch to lock nuts: use all-metal lock nuts or nylon insert lock nuts at impact-vibration locations
② Add threadlocker: apply high-strength anaerobic threadlocker to the engaged threads to fill the clearance and resist impact
③ Mechanical locking: add cotter pins or tab washers to provide a hard restraint independent of friction
④ Raise the grade: upgrade ordinary grade 4.8 bolts to high-strength grade 8.8 or above to increase preload
⑤ Regular inspection: set up a routine check and re-tighten critical hinge nuts every shift
⑥ Add anti-loosening marks: apply a mark line between the nut and the member, and re-tighten as soon as inspection reveals a shift
⑦ Anti-loosening verification: confirm no loosening from the re-tightening torque and mark displacement
⑧ Standardize design: note on the drawing that ordinary nuts are prohibited at impact locations
GB/T 6182-2014 Prevailing torque type all-metal hexagon nuts, style 2