E46-171 · Fastening & Anti-Loosening · Cylinder block stud · ★★
The end of the stud screwed into the housing was threaded in too shallow, engaging only a few threads; when the nut was removed the stud was pulled out, the housing threaded hole was galled, and the joint failed.
[Mechanism] The screwed-in end of the stud carries the pull-out load through the housing threads; if threaded in too shallow the number of engaged threads is insufficient and the pull-out resistance is below the working tensile load.
[Calculation] The screwed-in depth should be no less than 1.5 times the bolt diameter d (steel into steel); when too shallow the pull-out resistance drops proportionally.
[Design gap] The stud screwed-in depth was not specified and no locking measure was used.
① Specify the screwed-in depth: no less than 1.5d for steel into steel and no less than 2d for steel into aluminum
② Use a locking feature: make the screwed-in end with a fine thread or a shoulder, and screw it fully home against the housing
③ Prevent turning: form a hex section on the stud or lock it with a special tool so it does not turn when the nut is removed
④ Check engagement: after assembly confirm the screwed-in end is fully threaded in with no gap
⑤ Screw-in torque: apply appropriate tightening to the screwed-in end thread to ensure engagement
⑥ Repair the hole: re-tap a galled threaded hole or install a thread insert
⑦ Depth verification: confirm the pull-out requirement is met by the screwed-in depth
⑧ Standardize process: write the stud screwed-in depth into the assembly process
GB/T 897-1988 Double-end studs bm=1d