E46-172 · Fastening & Anti-Loosening · Valve flange · ★★
A valve flange used studs whose screwed-in ends were not locked; each time a nut was removed the stud turned with it, and over time the housing threaded holes wore and enlarged, the sealing face could not be pressed tight, and steam leaked.
[Mechanism] If the stud's screwed-in end has no anti-rotation feature, the reaction torque from removing the nut turns the stud, causing the screwed-in end to back out and wear the threaded hole.
[Calculation] Repeated disassembly accumulates back-out of the screwed-in end, about half a turn each time, and after several cycles the engagement length shortens markedly.
[Design gap] The stud was not designed with locking (interference, tack weld or shoulder).
① Provide an anti-rotation feature: use an interference fit or a root shoulder bearing on the housing face at the screwed-in end
② Tack-weld: tack-weld the stud root on the non-removable side to prevent turning (use with care where serviceability is needed)
③ Use a long nut: temporarily lock the screwed-in end with a long nut before fitting the other end, and loosen the long nut first when disassembling
④ Check wear: periodically check whether the housing threaded hole has enlarged, and install a thread insert if out of tolerance
⑤ Mark for anti-rotation: mark the joint between the stud and the housing so any turning is detected and dealt with
⑥ Control the removal force: use a suitable wrench to remove the nut and avoid jerking that turns the stud
⑦ Locking verification: use the marks to confirm the stud does not turn with the nut
⑧ Standardize process: write the stud anti-rotation requirement into the maintenance work card
GB/T 898-1988 Double-end studs bm=1.25d