E46-186 · Fastening & Anti-Loosening · Reducer cover · ★★
One bolt was left out when the housing halves were closed; the remaining bolts were tightened to the original torque, but that spot on the split face had no compression, forming a local gap that leaked oil during the test run.
[Mechanism] A missing bolt leaves that area without preload; neighboring bolts share the load and the local sealing face is not compressed, so it leaks.
[Calculation] One missing bolt makes the compression force zero at that spot; once the gap exceeds the gasket's recovery, it leaks.
[Design gap] The bolt count was not checked when closing the housing, and there was no check against missing bolts.
① Count the quantity: before closing, count the total number of bolts against the drawing and confirm it matches the number of holes
② Number in sequence: number the bolt holes and tick them off one by one during assembly to prevent omissions
③ Full visual inspection: after final tightening, confirm hole by hole that every one has a bolt
④ Fill in omissions: as soon as a missing bolt is found, install it and tighten it in sequence
⑤ Error-proofing: for multiple holes, use locating pins to align first, then install the bolts
⑥ First-piece confirmation: for the first housing closure, an inspector confirms that no bolts are missing
⑦ Quantity verification: confirm no omissions by matching the bolt count to the hole count
⑧ Standardize process: write bolt counting and ticking off into the housing-closing operation
GB/T 5782-2016 Hexagon head bolts