E46-187 · Fastening & Anti-Loosening · Coastal equipment · ★★
Ordinary carbon steel bolts were mixed into a stainless steel assembly; in the coastal salt-fog environment they formed a galvanic couple, the carbon steel bolts corroded and seized quickly, and the stainless steel parts also showed pitting.
[Mechanism] Dissimilar metals in an electrolyte (salt fog) form a galvanic cell, and the lower-potential metal (carbon steel) corrodes faster.
[Calculation] The galvanic corrosion rate rises with the potential difference and the electrolyte conductivity; the annual corrosion of carbon steel can be several times the normal amount.
[Design gap] In the corrosive environment, neither a single corrosion-resistant material nor insulating separation was consistently used.
① Same material: in corrosive environments use stainless steel or a uniform coating for bolts, nuts, and the joined parts alike
② Insulating separation: when dissimilar metals are unavoidable, add insulating washers to break the galvanic circuit
③ Coatings: use corrosion-resistant coatings such as Dacromet or hot-dip galvanizing on carbon steel parts
④ Choose the stainless grade: use chloride-resistant stainless steel such as 316 at the coast
⑤ Regular inspection: in salt-fog areas, check bolts for corrosion regularly and replace them promptly
⑥ Avoid water accumulation: design drainage into the structure to reduce electrolyte retention
⑦ Corrosion-protection verification: confirm by material consistency that there is no galvanic corrosion
⑧ Standardize design: write the same-material requirement for corrosive environments into the design guidelines
GB/T 3098.6-2014 Mechanical properties of fasteners - Stainless steel bolts, screws and studs