E46-196 · Fastening & Anti-Loosening · Steel beam joint · ★★★
The faying surfaces of the steel beam's high-strength bolted connection had loose rust and oil contamination that were not treated; the slip coefficient was far below design, the joint still slipped after the bolts were tightened, and the beam end shifted.
[Mechanism] High-strength bolts transfer force through slip resistance at the faying surface; rust and oil lower the friction coefficient and the joint slips under load.
[Calculation] When the slip coefficient μ drops from 0.45 to below 0.2, the slip resistance at the same preload is halved and slipping occurs.
[Design gap] The faying surface was not sandblasted to remove rust or protected, and it became contaminated in storage.
① Treat the faying surface: before assembly, sandblast or shot-blast the faying surface to the design roughness and remove oil
② Keep it clean: protect the treated faying surface from moisture and oil, and install it the same day or soon after
③ Re-verify the coefficient: on arrival, re-test slip-coefficient specimens and use only those that pass
④ No painting: no paint or filler within the faying surface area
⑤ Check contamination: before installation, check the faying surface for rust, oil, and mud
⑥ Tighten in sequence: tighten the joint bolts in a symmetrical order
⑦ Slip verification: confirm the design requirement is met by re-testing the slip coefficient
⑧ Standardize process: write the faying-surface treatment and re-testing into the joint construction specification
GB/T 1231-2006 High-strength large hexagon head bolts for steel structures