E46-197 · Fastening & Anti-Loosening · Steel bridge joint · ★★★
The high-strength bolts were final-tightened from the plate edges toward the center; bolts tightened earlier were pulled out of line by those tightened later, gaps appeared between the plate stacks, the joint did not fit snugly, and the slip resistance dropped.
[Mechanism] Final tightening should proceed from high-stiffness to low-stiffness regions and from the center toward the edges; the reverse order lets later tightening squeeze bolts already tightened out of position.
[Calculation] Reverse-order tightening leaves local gaps between the plate stacks, so the contact faces are not tight and the slip-resistant area is reduced.
[Design gap] The final-tightening sequence was not specified, and the operator worked at random.
① Fix the sequence: final-tighten symmetrically outward from the joint center or the high-stiffness region
② Tighten in passes: snug-tighten one pass to bring the plates into contact, then final-tighten in sequence
③ Use a calibrated wrench: final-tighten with a calibrated electric wrench that stops automatically at the set torque
④ Check the fit: after final tightening, check the gaps between the plate stacks with a feeler gauge and correct any that exceed the limit
⑤ Check the splined end: confirm the splined end of torque-shear bolts has twisted off
⑥ Record the sequence: number the joint bolts and tick them off in order
⑦ Fit verification: confirm snug contact by the gaps between the plate stacks
⑧ Standardize process: write the final-tightening sequence into the joint assembly process
GB/T 1231-2006 High-strength large hexagon head bolts for steel structures