E46-206 · Bonding & Sealing · Reducer housing · ★★
Sealant was applied to the joint face of the reducer's upper and lower housings, but an interrupted gun pass left break points; after assembly oil seeped locally from the joint face and dripped along the bolts.
[Mechanism] At the break points of the joint-face sealant there is no adhesive barrier, and the lubricating oil seeps out through them under pressure and capillary action.
[Calculation] A break longer than the sealing cross-section forms a through leak path, and leakage occurs at a local pressure of only 0.2MPa.
[Design gap] The continuous application path and the sealant-layer width were not specified.
① Continuous application: lay a uniform, continuous bead along the joint face with no interruption or break points
② Control the bead width: the bead must cover the joint face and be slightly wider than the sealing band
③ Close and press: press the housing halves together evenly so the sealant spreads and conforms
④ Check squeeze-out: after closing, check whether the squeeze-out around the perimeter is continuous and even
⑤ Let it cure: let it stand for the specified time until the sealant is initially cured before adding oil
⑥ Leak test: after adding oil, check for seepage to confirm none occurs
⑦ Sealing verification: confirm no leakage by pressure holding or an oil check
⑧ Standardize process: write the application path and width into the assembly process
JB/T 7316 Reducers - General technical conditions for assembly