E46-210 · Bonding & Sealing · Water pipe fitting · ★
PTFE tape was wrapped on the water pipe fitting before it was screwed in, but because the wrap direction was opposite to the screw-in direction, the tape was unwound and pushed out when tightened, and the joint leaked as soon as water was supplied.
[Mechanism] PTFE tape must be wrapped in the same direction as the screw-in direction; wrapped the other way, it is unwound when tightened and cannot fill the gap.
[Calculation] With a reversed wrap, the tape comes loose after only a few turns, and the thread gap is left unfilled and leaks.
[Design gap] The wrap direction and number of layers were not specified.
① Wrap in the same direction: wrap the PTFE tape in the same direction as the thread's screw-in direction so it tightens as the joint is tightened
② Control the number of layers: wrap a moderate number of layers (about 3~5) to cover the thread crests
③ Press in the start and end: press the tape's leading end into the thread's starting end, and keep the trailing end from protruding past the face
④ Do not plug the bore: the tape must not enter the pipe cavity and block the flow passage
⑤ Add sealing: at high-temperature or vibrating locations, add thread sealant as a supplement
⑥ Leak test: supply water and run a pressure test to confirm no leakage
⑦ Sealing verification: confirm no leakage by pressure test
⑧ Standardize process: write the wrap direction and number of layers into the assembly process
GB/T 37617 PTFE tape for thread sealing