E46-214 · Bonding & Sealing · Pump cover joint face · ★★
The machined joint face between the pump cover and the pump body had poor roughness and retained tool marks; even after sealant was applied, water still seeped along the tool marks, and after tightening the marks formed capillary leak paths.
[Mechanism] Excessive joint-face roughness leaves continuous tool marks; the sealant cannot fill the microscopic grooves, and the medium seeps out along the grooves by capillary action.
[Calculation] The roughness Ra should be no greater than 3.2μm, but the measured Ra reached 12.5μm, and the groove depth exceeded the sealant's filling capability.
[Design gap] The joint-face roughness and flatness were not specified.
① Control roughness: machine the joint face to Ra≤3.2μm and remove tool marks
② Maintain flatness: control flatness so that the mating faces fit uniformly
③ Choose a gap-filling sealant: use a high-thixotropy gap-filling sealant on rough faces
④ Clean the faces: remove chips and oil before assembly to ensure cleanliness
⑤ Even pressure: tighten the bolts symmetrically and in stages so the sealant spreads evenly
⑥ Pressure test: after assembly, run a pressure test to check for leakage
⑦ Sealing verification: confirm no leakage by pressure test
⑧ Standardize process: write the roughness and flatness into the drawing
JB/T 7316 Reducers - General technical conditions for assembly