E46-226 · Bonding and Sealing · Stud Locking · ★★
Anaerobic adhesive was applied to lock the stud threads, but cutting oil left on the threads was not cleaned; the oil isolated the adhesive from the metal and prevented catalytic contact, so it cured poorly and the locking force was too low, leaving the stud prone to loosening.
[Mechanism] The oil film on the thread surface isolates the anaerobic adhesive from the metal; the lack of metal-ion catalysis and the disturbed oxygen-free condition hinder curing.
[Calculation] The oil film leaves less than half the area properly cured, and the locking torque drops markedly.
[Design gap] The threads were not degreased before applying the adhesive.
① Degrease the threads: remove all thread oil with a cleaner before applying the adhesive
② Dry: let the threads dry after cleaning before applying the adhesive
③ Apply thinly on the engaged section: apply the adhesive only on the engaged thread
④ Wipe off excess: wipe off surplus adhesive from the outer surface before assembly
⑤ Curing time: let it stand for the specified time before applying load
⑥ Torque check: check the locking torque after curing
⑦ Locking verification: confirm the bolt does not loosen by the breakaway torque
⑧ Standardize process: write the cleaning requirement into the work instruction
JB/T 7311 Anaerobic adhesives for thread locking