Knowledge Base › Process and Assembly Error Case Study › Uneven Flange Bolt Force Causing One-Sided Leakage

Uneven Flange Bolt Force Causing One-Sided Leakage

E46-225 · Bonding and Sealing · Process Piping · ★★

Problem Description

A process-piping flange used a gasket, but only the bolts on one side were tightened; the flange face gaped on one side, the gasket was not compressed there, and the medium leaked from the open side.

Root Cause

[Mechanism] Uneven bolt tightening skews the flange face; the gasket is locally under-compressed and forms a leakage path.
[Calculation] Tightening one side only brings the compression on the gapping side close to zero, far below what sealing requires.
[Design gap] Crosswise, staged tightening was not specified.

Corrective Solution

① Crosswise tightening: tighten the bolts diagonally in sequence, in stages
② Staged torque: reach the torque in two steps, initial and final
③ Even torque: keep the torque the same on all bolts without bias
④ Control the compression: bring the compression rate evenly to the design value
⑤ Check parallelism: measure the flange-face parallelism while tightening
⑥ Pressure test: run a hydrostatic or pneumatic test after assembly
⑦ Seal verification: confirm no leakage by the pressure test
⑧ Standardize process: write the tightening sequence and torque into the procedure

Checklist

Reference

GB/T 9126 Non-metallic flat gaskets for pipe flanges