E46-238 · Bonding and Sealing · Precision Component · ★
A precision component was bonded with instant adhesive; the workshop humidity was high, and as the adhesive cured it deposited white powder around it (whitening), contaminating the component's appearance and weakening the bond.
[Mechanism] In high humidity the vaporized monomer of instant adhesive meets moisture and deposits as a white residue, both contaminating the part and weakening the interface.
[Calculation] Above 70% relative humidity the whitening is pronounced and the bond strength drops.
[Design gap] In the high-humidity environment the humidity was not controlled and no low-whitening adhesive was selected.
① Control humidity: keep the working-environment humidity below 60%
② Choose low-whitening: in humid places choose a low-whitening instant adhesive
③ Apply less: apply thinly to reduce monomer evaporation
④ Ventilate: ventilate the work area to lower the local humidity
⑤ Clean promptly: wipe off the white residue promptly
⑥ Strength check: confirm the bond strength
⑦ Bond verification: confirm acceptance by the strength result
⑧ Standardize process: write the humidity control into the process
GB/T 7124-2008 Adhesives - Determination of tensile shear strength (rigid material to rigid material)