E46-250 · Bonding and Sealing · Assembly Bonding · ★★
The bonded assembly was lifted and moved before its curing time was reached; the handling vibration and load displaced the still-soft adhesive layer and it debonded, so the parts shifted and rework was needed.
[Mechanism] An uncured adhesive has no strength; handling disturbs the interface and shifts it, leaving a void or offset after curing.
[Calculation] Before curing the adhesive strength is nearly zero, so even a light load displaces the joint.
[Design gap] No curing dwell period or handling conditions were specified.
① Cure fully: only move the part after the specified curing time is reached
② Dwell period: set up a dwell area and mark the parts awaiting cure
③ Handle gently: lift and set down gently during transfer to reduce vibration
④ Keep the fixture: leave the fixture in place during curing
⑤ Marking: clearly mark parts awaiting cure to prevent accidental movement
⑥ Time record: record the start time and the time the part may be moved
⑦ Bond verification: transfer the part only after curing is confirmed
⑧ Standardize process: write the dwell period into the process
GB/T 7124-2008 Adhesives - Determination of tensile shear strength (rigid material to rigid material)