Knowledge Base › Process and Assembly Error Case Study › Accumulated Error from Datum Changes Between Operations

Accumulated Error from Datum Changes Between Operations

E46-300 · Machining Process · Machining Line · ★★★

Problem Description

Multi-operation machining changed the datum each time, so errors accumulated operation by operation; the finished part's key dimension was out of tolerance by 0.15mm, causing assembly interference.

Root Cause

[Mechanism] Each operation locates on a different face, so the datum non-coincidence errors add up cumulatively.
[Calculation] Three operations with 0.05mm each accumulate in the same direction to 0.15mm, exceeding tolerance.
[Design gap] The datum was not unified and the datum-chain conversion was not marked.

Corrective Solution

① Unify the datum: use the same precision datum across operations as far as possible
② Mark the chain: mark the datum-chain conversion on the process documents
③ Compute the accumulation: calculate the accumulated error to set the tolerance
④ Precision datum: establish a reliable precision datum in the first operation
⑤ Re-measure: re-measure the key dimensions at each operation
⑥ Reorder: change the operation sequence to reduce accumulation
⑦ Dimension verification: confirm the final dimension by CMM
⑧ Standardize process: write the unified datum into the process route, controlling at the source