Knowledge Base › Process and Assembly Error Case Study › High Humidity in the Painting Environment, Blushing

High Humidity in the Painting Environment, Blushing

E46-368 · Surface Treatment & Coating · Polyurethane topcoated part · ★★

Problem Description

The polyurethane topcoat blushed and lost gloss after application; the ambient humidity was 90% (should be ≤85%) and moisture mixed into the film.

Root Cause

[Mechanism] High humidity causes solvent evaporation to absorb heat and moisture to condense into a white haze.
[Calculation] Above 85% humidity the blushing rate rises sharply, and at 90% large areas blush.
[Design gap] The application-environment humidity was not controlled.

Corrective Solution

① Control humidity: keep application humidity ≤85% to prevent blushing
② Dehumidify: run a dehumidifier to lower ambient humidity and stay dry
③ Choose the time: avoid high-humidity periods for application to ensure stable film formation
④ Blushing check: check for blushing when surface-dry to detect problems early
⑤ Re-coat: sand and re-spray blushed parts to restore gloss
⑥ Control dew point: keep the workpiece temperature more than 3℃ above the dew point to prevent condensation
⑦ Appearance verification: confirm absence of blushing by visual inspection, confirmed by data
⑧ Standardize process: write the humidity requirement into the painting environment, controlling at the source

Checklist

Reference

GB/T 30790.1-2014 Paints and varnishes - Protective coating systems