E46-428 · Commissioning & Run-In · Stepper drive mechanism · ★★
High-speed pulses were fed to the stepper motor directly; the rotor could not keep up, lost steps and overshot the upper position, and the mechanism hit the limit.
[Mechanism] A starting frequency beyond the motor's response capability causes lost steps and loss of position control.
[Calculation] Once the starting frequency exceeds the no-load pull-in frequency the motor loses steps and the error accumulates.
[Design gap] No frequency ramp and no acceleration/deceleration were set.
① Ramp the frequency: raise the pulse frequency in stages from low to high to avoid losing steps
② Accel/decel: use S-curve acceleration and deceleration for smooth starting and stopping
③ Check pull-in: check the motor's no-load pull-in frequency and start below it
④ Limit travel: set the soft limit before the upper position to prevent a crash
⑤ Monitor feedback: monitor the actual position with an encoder and stop immediately on lost steps
⑥ Record: record the frequency curve and the step count
⑦ Quality verification: confirm acceptance by positioning without lost steps, confirmed by data
⑧ Standardize process: write acceleration/deceleration into the control program, controlling at the source
GB/T 17421.1-1998 Test code for machine tools - Part 1: Geometric accuracy