After a long shutdown the screw compressor was started without barring over; the rotors seized because the lubricating oil had congealed, and the excessive starting current tripped the breaker.
[Mechanism] After a long shutdown the oil settles and the oil film between the rotors solidifies, so the starting torque exceeds what the motor can deliver.
[Calculation] When the rotors are seized the starting torque is several times the rated value and the current exceeds rated, tripping the breaker.
[Design gap] The barring-over and warm-up start procedure was not followed.
① Bar over first: turn the shaft by hand several revolutions before starting to confirm it rotates freely
② Warm up: jog the unit or heat the oil separator to bring the oil temperature back up
③ Jog: energize briefly to check rotation and current
④ Oil temperature: measure the oil temperature and heat it first if it is low
⑤ Unload: with the unloader valve, run unloaded first and then apply load
⑥ Record: record the barring-over and the oil temperature
⑦ Quality verification: confirm acceptance by smooth barring over and normal current, confirmed by data
⑧ Standardize process: write the barring-over procedure into the start-up specification, controlling at the source
GB/T 3853-2010 Displacement compressors - Acceptance tests