E46-444 · Commissioning & Run-In · Bolt tightening during commissioning · ★★
The torque wrench used for commissioning was overdue for calibration and read low, so the connecting bolts were actually under-torqued and came loose in operation.
[Mechanism] An inaccurate wrench makes the set torque lower than actually required, leaving insufficient preload.
[Calculation] With the indication 15% low the preload is insufficient and the locking feature fails.
[Design gap] The torque tools were not calibrated periodically.
① Calibrate first: send the torque wrench for calibration so that it is within its valid period before commissioning
② Verify indication: check the indication error with a standard torque meter
③ Select range: choose a wrench whose mid-range suits the bolt, avoiding the extremes
④ Recheck: randomly spot-check the torque of the tightened bolts to confirm conformance
⑤ Record: record the calibration date and the spot-check values
⑥ Replace: tag out and stop using an inaccurate wrench
⑦ Quality verification: confirm acceptance by spot-checked torque, confirmed by data
⑧ Standardize process: write tool calibration into commissioning preparation, controlling at the source
GB/T 16857.1-2018 Geometrical product specifications (GPS) - Acceptance and reverification tests for coordinate measuring machines