Knowledge Base › Process and Assembly Error Case Study › Hydraulic System Not Flushed Contaminating the Valves

Hydraulic System Not Flushed Contaminating the Valves

E46-443 · Commissioning & Run-In · Hydraulic system · ★★

Problem Description

The new system was put into service without circulating flushing, so welding slag from the piping entered the valve spools, causing sticking and loss of directional control.

Root Cause

[Mechanism] Impurities left in the piping enter the valves with the oil, jamming the spools and blocking operation.
[Calculation] Once particulates exceed NAS class 9 the valves jam and the system loses control.
[Design gap] No circulating flush of the piping was performed.

Corrective Solution

① Flush first: connect an external flushing circuit and circulate until cleanliness meets the target
② Filter: circulate the oil through a fine filter cart
③ Sample: take an oil sample at the end of flushing to check the NAS class, and install the valves only once it passes
④ Bypass: bypass the valve positions during flushing to prevent jamming
⑤ Oil check: check the oil cleanliness before filling
⑥ Record: record the flushing duration and cleanliness class
⑦ Quality verification: confirm acceptance by oil cleanliness, confirmed by data
⑧ Standardize process: write the flushing procedure into hydraulic commissioning, controlling at the source

Checklist

Reference

GB/T 3766-2015 General technical conditions for hydraulic systems