E46-450 · Commissioning & Run-In · Automated Equipment · ★★★
The equipment was delivered after commissioning without verifying the emergency-stop function; when an abnormality occurred in production the emergency stop had no effect and the workpiece was destroyed.
[Mechanism] The emergency-stop circuit was left untested, so energy cannot be cut off in a fault state and the hazard persists.
[Calculation] With the emergency stop ineffective, shutdown time exceeds the standard and the accident escalates.
[Design gap] No emergency-stop function test was performed.
① Mandatory test: at the end of commissioning press each emergency stop to check that energy is cut off and motion stops
② Check circuit: verify the emergency-stop hard wiring and relay operation
③ Reset: confirm the emergency stop requires manual reset, preventing automatic restart
④ Full stop: the emergency stop halts all moving parts and holds their position
⑤ Indication: the indicator and alarm work after an emergency stop
⑥ Record: record the test and its results
⑦ Quality verification: confirm safety by an effective emergency stop, confirmed by data
⑧ Standardize process: write the emergency-stop test into the commissioning checklist, controlling at the source
GB/T 5226.1-2019 Electrical safety of machinery - Electrical equipment of machines - Part 1