E46-452 · Dimension Chain & Tolerance Coordination · Housing · ★★
A housing hole pattern was designed relative to the design datum with position φ0.1 mm, but measured against the assembly datum (bottom-face dowel holes) it was offset 0.16 mm, exceeding tolerance by 0.06 mm, causing off-center bearing installation and heating.
[Mechanism] The design datum and the assembly datum do not coincide, creating a datum non-coincidence error that adds one extra link to the dimension chain.
[Calculation] Datum transfer error Δ=0.16-0.10=0.06 mm, made up of the locating dowel-hole position 0.05.
[Design gap] The three types of datum were not unified, and the process datum was not marked on the drawing.
① Unify datums: unify the design, process and measurement datums onto the same face, controlling at the source
② Mark datum: explicitly mark the assembly datum on the drawing and give its position tolerance, confirmed by data
③ Pin locating: use two pins and one face for locating to keep the datums coincident, detecting problems early
④ Measure parts: measure hole positions against the assembly datum, preventing datum error
⑤ Adjust position: add a process boss as the unified datum face, ensuring consistency
⑥ Verify position: CMM-measure the position tolerance to ≤φ0.1mm, correcting early
⑦ Quality verification: confirm hole-position conformance by datum coincidence, confirmed by data
⑧ Standardize process: write datum unification into the process specification, controlling at the source
GB/T 1182-2018 Geometrical product specifications (GPS) - Geometrical tolerancing