E46-455 · Dimension Chain & Tolerance Coordination · Flanged connection · ★★
After flange-bolt preloading, the coaxiality of the two flanges was designed φ0.05 mm but measured 0.12 mm, exceeding tolerance by 0.07 mm, causing eccentric wear of the sealing face and leakage.
[Mechanism] Bolt preload compresses the flanges unevenly, causing relative tilt that changes coaxiality.
[Calculation] Preload force F=120 kN, compression deformation δ=F/(EA)×t=0.08 mm, tilt causing eccentricity 0.12 mm.
[Design gap] The effect of preload deformation on coaxiality was not checked, and flange stiffness was insufficient.
① Calculate deformation: check flange compression deformation from the preload force, controlling at the source
② Even tightening: tighten evenly in diagonal steps to reduce skewing, confirmed by data
③ Add stiffness: thicken the flanges to raise bending stiffness, detecting problems early
④ Select gasket: use a metal serrated gasket for even pressure, preventing eccentric wear
⑤ Measure coaxiality: after preloading measure coaxiality ≤φ0.05 mm, ensuring sealing
⑥ Verify seal: pressure-test for no leakage, correcting early
⑦ Quality verification: confirm reliable sealing by measured coaxiality, confirmed by data
⑧ Standardize process: write the preload process into the assembly work instruction, controlling at the source
GB/T 150.3-2011 Pressure vessels - Design