E46-454 · Dimension Chain & Tolerance Coordination · Steel structure frame · ★★
A steel frame was designed with overall length 2000±0.5 mm, but after welding measured 1998.2 mm, shortened by 1.8 mm, exceeding tolerance by 1.3 mm, so the connecting holes were offset and would not assemble.
[Mechanism] Weld cooling shrinkage shortens the member longitudinally, and the shrinkage of many welds accumulates noticeably.
[Calculation] One weld shrinks 0.2 mm, 10 welds total 2.0 mm, close to the measured 1.8 mm.
[Design gap] Weld shrinkage was not pre-compensated for, and blanks were not cut longer.
① Calculate shrinkage: check the shrinkage from the weld cross-section, controlling at the source
② Cut longer: add 0.2 mm per weld at blanking for compensation, confirmed by data
③ Balanced welding: use symmetric segmented welding to reduce distortion, detecting problems early
④ Fixture: constrain distortion with welding fixtures, preventing out-of-tolerance
⑤ Straighten: mechanically straighten after welding into tolerance, ensuring length
⑥ Verify length: measured overall length after welding 2000±0.5 mm, correcting early
⑦ Quality verification: confirm hole alignment by measured length, confirmed by data
⑧ Standardize process: write weld-shrinkage compensation into the blanking sheet, controlling at the source
GB/T 19866-2005 Welding procedure specification