E46-468 · Dimension Chain & Tolerance Coordination · Assembly · ★★
The design controlled only the component links and failed to recognize the closing link as the key clearance; the assembled clearance measured 0.5 mm, out of tolerance, and both function and appearance were poor.
[Mechanism] The closing link of the dimension chain was identified wrongly, so the key requirement was not constrained.
[Calculation] Closing-link tolerance T0=ΣTi=0.5 > the design requirement 0.1.
[Design gap] The closing link was not correctly identified and ensured.
① Identify link: first identify the true closing link as the key requirement, controlling at the source
② Calculate chain: back-calculate component-link tolerances from the closing link, confirmed by data
③ Mark link: mark the closing-link tolerance on the drawing, detecting problems early
④ Measure closing: measure the closing-link value, preventing hidden out-of-tolerance
⑤ Control components: tighten the component links, ensuring closure
⑥ Verify closing: measured closing link ≤0.1 mm, correcting early
⑦ Quality verification: confirm conformance by the closing link, confirmed by data
⑧ Standardize process: write closing-link identification into the design flow, controlling at the source
GB/T 5847-2004 Dimensional chain — Calculation method