E46-469 · Dimension Chain & Tolerance Coordination · Bushing · ★★
An H7/p6 interference fit was designed for press fitting, but a clearance fit was mistakenly specified, so the part could be pulled out by hand and the function failed; elsewhere a clearance was mistaken for interference, cracking the part under press fit.
[Mechanism] Choosing the wrong fit type (interference/clearance) makes the joint fail or fracture.
[Calculation] It should have been interference 0.02 to 0.05 but became clearance 0.03, leaving zero joint force.
[Design gap] The fit type was not selected from the load.
① Define type: set interference or clearance from the load, controlling at the source
② Calculate interference: check the interference amount and press-fit force, confirmed by data
③ Mark fit: mark the correct fit tolerance band on the drawing, detecting problems early
④ Measure parts: inspect the actual fit at incoming inspection, preventing wrong assembly
⑤ Press fit: control press-fit force and temperature for interference parts, ensuring tightness
⑥ Verify joint: confirm the joint force by pull test, correcting early
⑦ Quality verification: confirm reliability by measured fit, confirmed by data
⑧ Standardize process: write the fit type into the design, controlling at the source
GB/T 1801-2020 Geometrical product specifications (GPS) - Tolerance bands