Q — volumetric flow rate (m³/s)
A₁, A₂ — area of section 1 and 2 (m²)
V₁, V₂ — flow velocity at section 1 and 2 (m/s)
Pipe D₁=50mm, V₁=2m/s, reduced to D₂=25mm
A₁=π×0.05²/4=0.00196m²
Q=0.00196×2=0.00392m³/s
A₂=π×0.025²/4=0.00049m²
V₂=Q/A₂=0.00392/0.00049=8m/s
p — pressure (Pa)
ρ — density (kg/m³)
V — flow velocity (m/s)
g — gravitational acceleration (m/s²)
z — elevation (m)
Formula: Re<2320 laminar, >4000 turbulent
Parameter meanings and units. This formula is used very frequently in mechanical design, verification and selection.
hf — friction head loss (m)
λ — friction factor
L — pipe length (m)
D — pipe internal diameter (m)
V — flow velocity (m/s)
g — gravitational acceleration (m/s²)
p1/(ρg) + v1²/(2g) + z1 = p2/(ρg) + v2²/(2g) + z2 = H (constant)
p — pressure (Pa)
ρ — density (kg/m³)
v — flow velocity (m/s)
g — 9.81 m/s²
z — elevation (m)
H — total head (m)
p1/ρg + v1²/2g + z1 = p2/ρg + v2²/2g + z2 + hw
hw — loss head (friction + local)
p/ρg — pressure head (static pressure energy)
v²/2g — velocity head (dynamic pressure energy)
z — elevation head (potential energy)
Q = Cd·A2·√(2·(p1-p2)/ρ/(1-(A2/A1)²))
Cd — discharge coefficient (0.95~0.99)
A1, A2 — inlet / throat area
v = √(2·Δp/ρ)
Δp — total pressure minus static pressure
Q = Cd·A·√(2·Δp/ρ)
Cd — orifice discharge coefficient (0.6~0.65)
A — orifice opening area
Pressure at the highest point < atmospheric pressure
Maximum suction height < atmospheric head (about 10 m of water column)
H = (p2-p1)/(ρg) + (v2²-v1²)/(2g) + (z2-z1) + hw
Water pipe d1=100mm, d2=50mm, Q=0.01m³/s, horizontal
v1 = 4Q/(πd1²) = 4×0.01/(π×0.01) = 1.27m/s
v2 = 4×0.01/(π×0.0025) = 5.09m/s
p1-p2 = ρ·(v2²-v1²)/2 = 1000×(25.9-1.6)/2 = 12150Pa
① Applicable to incompressible fluids (liquids / low-speed gases)
② The flow must be steady
③ Apply along the same streamline
④ For high-speed gases, compressibility must be considered (use the energy equation)
Re = v·d/ν = ρvd/μ
v — flow velocity (m/s)
d — pipe diameter (m)
ν — kinematic viscosity (m²/s)
μ — dynamic viscosity (Pa·s)
Laminar: Re<2300
Transitional: 2300<Re<4000
Turbulent: Re>4000
Water: 1.0×10⁻⁶
Air: 15×10⁻⁶
Hydraulic oil (ISO VG46): 46×10⁻⁶
Gasoline: 0.65×10⁻⁶
Glycerin: 680×10⁻⁶
hf = λ·(L/d)·v²/(2g)
Δp = λ·(L/d)·(ρv²/2)
λ — friction factor
L — pipe length
d — pipe diameter
Laminar (Re<2300): λ = 64/Re
Hydraulically smooth pipe (4000<Re<10⁵): λ = 0.3164/Re^0.25 (Blasius)
Rough pipe (Re>10⁵): λ = 1/(1.14+2lg(d/ε))² (Nikuradse)
ε — absolute roughness of the pipe wall (mm)
New seamless steel pipe: 0.05
Old steel pipe: 0.5
Cast iron pipe: 0.3
Concrete pipe: 1.5
Plastic pipe: 0.01
Glass pipe: 0.001
hj = ζ·v²/(2g)
ζ — local loss coefficient
Common local loss coefficients ζ:
90° elbow (standard): 0.3~0.5
90° elbow (radius R=d): 0.15
Tee (straight through): 0.1~0.2
Tee (branching): 1.5
Gate valve (fully open): 0.1~0.2
Globe valve (fully open): 3~10
Check valve: 2
Sudden expansion: ζ=(1-A1/A2)²
Sudden contraction: ζ=0.5(1-A2/A1)
Inlet (sharp edge): 0.5
Outlet (sharp edge): 1.0
hw = Σhf + Σhj
Water pipe d=50mm, L=100m, v=2m/s, water temperature 20℃
Re=2×0.05/1e-6=100000 (turbulent)
ε=0.05 (new steel pipe), ε/d=0.001
λ=1/(1.14+2lg(50))²=1/(1.14+3.396)²=1/20.6=0.0485
hf=0.0485×100/0.05×4/19.62=19.8 m of water column
Δp=19.8×9800=194kPa
① Keep the flow velocity within the economical range
Water 1~3m/s, oil suction <1.5, oil pressure 3~6
② Reduce the number of elbows and reducers
③ Avoid sudden expansion/contraction
④ Increasing the diameter reduces the resistance (Δp∝1/d⁵)
H = (p2-p1)/(ρg) + (v2²-v1²)/(2g) + (z2-z1) + hw
Simplified (similar inlet and outlet diameters):
H ≈ (p2-p1)/(ρg) + (z2-z1) + hw
H — head (m)
p1, p2 — suction / discharge pressure (Pa)
ρ — liquid density (kg/m³)
Pe = ρ·g·Q·H
Q — flow rate (m³/s)
H — head (m)
P = Pe/η = ρgQH/η
η — pump efficiency (0.6~0.85)
Pm = P·K/ηt
K — safety factor (1.1~1.3)
ηt — transmission efficiency (direct coupling 1.0, coupling 0.98, belt 0.95)
Centrifugal pump Q=0.01m³/s (36m³/h), H=30m, water
Pe = 1000×9.81×0.01×30 = 2943W = 2.94kW
η=0.7
P = 2.94/0.7 = 4.2kW
Pm = 4.2×1.2/0.98 = 5.14kW
Select a 5.5kW motor
When the speed n changes:
Q2/Q1 = n2/n1
H2/H1 = (n2/n1)²
P2/P1 = (n2/n1)³
When the impeller diameter D changes (cut law):
Q2/Q1 = D2/D1
H2/H1 = (D2/D1)²
P2/P1 = (D2/D1)³
ns = 3.65·n·√Q/H^(3/4)
ns — specific speed
n — speed (rpm)
Q — flow rate (m³/s, for double suction use Q/2)
H — head (m, for multistage use H/number of stages)
Centrifugal pump: ns=30~300
Mixed-flow pump: ns=300~500
Axial pump: ns=500~1500
Available NPSH:
NPSHa = pa/ρg - pv/ρg - Hs - hw,s
pa — atmospheric pressure head
pv — vapour pressure head of the liquid
Hs — geometric suction height
hw,s — suction line loss
Required NPSH: NPSHr (a pump performance parameter)
NPSHa > NPSHr + 0.5m (safety margin)
Noise and vibration, performance loss, impeller damage
① Reduce the installation height (or install with a flooded suction)
② Reduce the resistance of the suction line
③ Lower the liquid temperature
④ Select a pump with a small NPSHr
⑤ Add an inducer
Vth = Vh·n·i = (π/4·D²·S)·n·i
D — cylinder diameter
S — piston stroke
n — speed (rpm)
i — number of cylinders (multiply by 2 for double acting)
V = λ·Vth
λ — delivery coefficient = λv·λp·λt·λl
λv — volumetric efficiency (0.8~0.95)
λp — pressure coefficient (0.95~0.98)
λt — temperature coefficient (0.94~0.97)
λl — leakage coefficient (0.95~0.98)
λv = 1 - α·((p2/p1)^(1/m) - 1)
α — relative clearance volume (0.05~0.15)
m — expansion exponent (1.2~1.4)
p2/p1 — pressure ratio
Pad = (k/(k-1))·p1·V·((p2/p1)^((k-1)/k) - 1)
k — adiabatic exponent
Air: k=1.4
Nitrogen: k=1.4
Hydrogen: k=1.41
Ammonia: k=1.29
Piso = p1·V·ln(p2/p1)
Pi = Pad/ηi
ηi — indicated efficiency (0.85~0.95)
P = Pi/ηm
ηm — mechanical efficiency (0.85~0.95)
Pm = P·K
K — safety factor (1.1~1.2)
ηiso = Piso/P
Generally ηiso=0.5~0.7
Total pressure ratio ε=p_final/p_initial
Optimum intermediate pressure: p_mid = √(p1·p2)
For n stages: pressure ratio per stage εi = ε^(1/n)
Advantages of multistage compression:
① Saves power (intercooling approaches isothermal)
② Lowers the discharge temperature
③ Improves the volumetric efficiency
T2 = T1·(p2/p1)^((k-1)/k)
Limit: T2<180℃ (lubrication condition)
Beyond this, multistage compression with intercooling is required
Single-stage air compressor, p1=0.1MPa, p2=0.8MPa, V=1m³/min
ε=8, k=1.4
T2=293×8^(0.4/1.4)=293×1.81=531K=258℃ → too high
Two stages should be selected, each with ε=√8=2.83
T2=293×2.83^0.286=293×1.35=396K=123℃ ✓
① Air delivery = air consumption × 1.2 (spare capacity + leakage)
② Discharge pressure = maximum demand + 0.1MPa margin
③ Screw type: continuous operation, low vibration
④ Reciprocating type: intermittent operation, high pressure
⑤ Centrifugal type: large flow at low pressure
Related quick references: Mechanics FundamentalsVibrationThermodynamicsElectrical Engineering BasicsQuick Calculation FormulasHydraulic & Inertia CalculationsGear StrengthShaft StrengthKey ConnectionsSpringsBolt StrengthWeld StrengthBeam & Plate Bending