Using the difference in settling velocity of solid particles, the fine particles leave with the overflow while the coarse particles are returned as spiral sand.
Classification size d_95 (the size below which 95% of the overflow passes)
Screw diameter D = 1.0~3.0m
Chute inclination 12°~18°
Return sand rate Q_s = 60×π×D²/4×s×n×ψ×ρ
Sispitch (=D), nisspeed (2~10rpm)
ψ is the filling factor (0.2~0.4)
Forms a closed-circuit grinding and classification system with the ball mill
The slurry enters the cyclone tangentially and spins at high speed; coarse particles have a large centrifugal force and are discharged through the spigot along the wall, while fine particles leave through the central overflow pipe.
Separation size d_50 = 15×(D²×μ×d_o)/(Q×Δρ×√h)
D is the cyclone diameter, μ the slurry viscosity and d_o the overflow pipe diameter
Coarse classification (>100μm): large cyclones D = 500~1000mm
Fine classification (20~100μm): D = 250~500mm
Ultra-fine classification (<20μm): D = 50~250mm
Heavy wear (replaced every 3~7 days); silicon carbide or wear-resistant ceramics are needed
The slurry is mixed with reagents and air is introduced; the hydrophobic particles attach to the bubbles, rise to the surface as a froth layer and are scraped off.
Collectors: xanthate (sulphide ores), fatty acid (oxidised ores)
Frothers: pine oil, MIBC
Regulators: lime (pH adjustment), copper sulphate (activation)
Single cell volume: roughing 4~40m³, cleaning 2~8m³
Air rate: 0.5~2.0m³/m²·min
Stirring speed: 150~500rpm
Roughing→cleaning2~3times→scavenging2~3times
Separation is by the difference in magnetic susceptibility. Strongly magnetic minerals (magnetite) are separated by weak magnetic separation, weakly magnetic minerals (hematite / limonite) by high-intensity magnetic separation.
Magnetic induction: 0.1~0.2T
ThroughputQ=K×D×L×v×ρ
Kis the coefficient (0.1~0.3), Disrollerdiameter, LisrollerLength
Magnetic induction: 0.8~1.8T (electromagnetic) or 0.3~0.6T (permanent magnet)
Media: steel wool / steel mesh / expanded steel mesh
Weak magnetic separation: magnetite separation (recovery > 99%)
High-intensity magnetic separation: hematite / limonite / manganese ore
The solid particles settle to the bottom under gravity and the clarified overflow leaves from the top.
A=Q×(C_in-C_u)/G_s
Q is the feed rate, C_in the feed density and C_u the underflow density
G_s is the solids flux (kg/m²·h)
① Flocculant dosage: adding polyacrylamide (10~50g/t) increases the settling velocity 3~5 times
② Concentrator depth: a cone-bottom thickener gives a higher underflow density
③ Rake speed: 0.5~3rpm (a faster rake gives a lower underflow density)
Rake jam (excessive underflow density or rake failure)
Sludge blanket (flocculant short or feed rate overloaded)
Magnetite is cleaned using an upward water flow and an alternating magnetic field, raising the concentrate grade by 2~5 percentage points.
Magnetic field strength: 0.05~0.15T
At a feed grade of 55%~60% the concentrate grade can reach 67%~69%
Used for magnetite roughing and scavenging, with a magnetic wrap angle of 120°~135°
Rollerdiameter600~1200mm, rollerLength600~2400mm
ThroughputQ=K×D×L×v×ρ, K=0.2~0.4
① Feed size ≤ 3mm (roughing) or ≤ 0.5mm (cleaning)
② Slurry density 30%~45%
③ The spigot size affects the concentrate grade and recovery
Large concentrators commonly use several cyclones in parallel to form a cyclone bank.
① Manifold design: the inlet pressure difference between cyclones must be ≤ 5%, otherwise the classification efficiency falls sharply
② Fit a surge bin at the feed inlet (volume 1~2 times the feed rate)
③ All cyclones of the same type (identical diameter, overflow pipe and spigot sizes)
Q total = n × Q per unit
n is the number of units and Q per unit the throughput of one unit
Install 20%~30% standby cyclones in the cyclone bank
Check the spigot wear every shift
The slurry is fed at the top of the column, bubbles are generated at the bottom by a micro-porous sparger, and the particles contact the bubbles countercurrently to achieve flotation.
① Flotation column: very fine bubbles (0.3~0.8mm), suited to fine flotation (-38μm)
② Flotation machine: larger bubbles (1~2mm), suited to conventional size fractions
③ Flotation column: simple structure with no moving parts, low maintenance
④ Flotation column: tall (10~15m), requiring a high building
① Molybdenum cleaning (one column cleaning can replace 3~5 flotation machine cleanings)
② Reverse flotation of iron ore (raises the concentrate grade)
③ Flotation of fine coal sludge
Separation is by density difference. The magnetite powder is mixed with water to form a suspension of defined density; minerals denser than the suspension sink, those less dense float.
Sortingdensityδ_x=1.3~2.0g/cm³
Magnetite powder fineness -325 mesh ≥ 90%
Suspension viscosity ≤ 10mPa·s
Possible deviation E_p = 0.02~0.08 (the smaller the value, the higher the separation accuracy)
Throughput: heavy-media cyclone 200~500t/h
The magnetic separator recovers magnetite powder (recovery > 99.5%)
Media consumption: 0.5~2.0kg per tonne of ore
Upstream construction (most common): rock-fill for the initial dam, tailings placed on the upstream face afterwards
Center-line construction: good safety but complicated construction
Downstream construction: the highest safety, the largest investment
Dry beach length: ≥ 100m (Category III and above tailings facilities)
Safe overtravel: ≥ 0.5m
Phreatic line depth: ≥ 6m (Category III and above)
Category III facility: the 1-in-200-year flood
Category IV facility: the 1-in-100-year flood
Category V facility: the 1-in-50-year flood
① Check the phreatic line depth daily
② Measure the dam displacement regularly (monthly)
③ Check that the drainage wells and pipes are in good condition