Noise acceptance is one of the easiest things to fail lately. The contract says operator station within 1 m no higher than 75 dB(A); you check the manuals for ages — motor rated 70, reducer 72, fan 68 — and figure it is fine any way you add it, but on start-up it reads 77 and acceptance stalls.
The problem is in three places: first, decibels cannot be added or averaged; second, the maker rates sound power level while acceptance measures sound pressure level, with distance in between; third, when three sources sound together, none dominates the others.
Below we calculate through a 15 kW powder-mixing unit from scratch, then expand the formulas and value tables.
A powder-mixing unit: 15 kW induction motor directly coupled to a single-stage helical reducer, input speed 1465 r/min, gear pitch-line speed 5.6 m/s, load per unit face width 220 N/mm, accuracy grade 7; input shaft uses a 6210 deep-groove ball bearing (d=50) with radial load 1800 N; the unit has its own axial cooling fan, airflow 2000 m³/h, total pressure 420 Pa. Workshop background noise 68 dB(A). Acceptance: ≤ 75 dB(A) at 1 m.
= 60 + 8×1.176 + 4×(−0.010) + 0 + 2.0 = 71.4 dB(A)
Note the magnitude of the two coefficients: the power term is 8·lg, so doubling power only raises 8×0.301 = 2.4 dB; the speed term is 4·lg, so doubling speed only raises 1.2 dB. That is, swapping 15 kW for 30 kW adds only 2.4 dB; changing the motor from 4-pole to 2-pole (double speed) adds only 1.2 dB. Motor noise is not sensitive to duty parameters — swapping the motor basically cannot solve a noise problem.
= 72 + 3×0.049 + 2×0.342 + 0 − 1.0 = 71.8 dB(A)
Raising line speed from 5 m/s to 5.6 m/s adds only 0.15 dB; raising load per unit face width from 100 to 220 N/mm adds 0.68 dB. But dropping accuracy from grade 7 to 8 directly +1.5 dB; good crowning/modification reaching grade 6, −1.5 dB。
Many designers reject this conclusion: gear noise is not a mechanics problem but one of accuracy and tooth-surface quality. To shave decibels off the gear, thickening the housing is useless — grinding plus crowning is what works.
By the way, the mesh frequency: f = z₁·n/60 = 23×1465/60 = 561.6 Hz. This frequency must avoid the first natural frequency of the casing and bracket; landing between 540–580 Hz causes resonant whine, which sounds like a sharp whistle and is more annoying than the overall level.
= 55 + 5×0.166 + 2×0.222 + 3×0.255 + 0 = 57.0 dB(A)
15 dB below the gear, energy share only 1%. This number is the dividing line for noise reduction — a 1% source, even if completely eliminated, lowers the overall level by only 0.04 dB, i.e. nothing. A rolling bearing, unless pitted, oil-starved, or with a loose cage, is never the main source in normal operation; conversely, if you hear periodic 'clack-clack' impacts on site, that is not a noise issue — the bearing is already failed and you should stop the machine.
= 65 + 10×0.301 + 5×(−0.076) + 5 = 72.6 dB(A)
The flow term's coefficient is 10·lg, so doubling flow always raises 3.0 dB — no exception, regardless of fan efficiency, blade shape, or maker — it is the result of sound power growing linearly with volumetric flow. So trying to cut flow noise by 'swapping in a good fan' is futile; you can only reduce the flow itself or move the fan farther away.
The type term also matters: at the same flow and pressure, axial is higher than centrifugal by 5 dB, and mixed-flow is 2 dB higher than centrifugal. That 'casually fitted' axial fan on the unit is often the loudest part of the whole machine.
The four sources' sound pressure levels are 71.4, 71.8, 57.0, 72.6. The arithmetic mean is 68.2, this number is wrong, and wildly wrong— it is lower than any single one of the two main sources, as if conjuring 8.6 dB of noise reduction from nothing.
Energy shares: fan 38%, gear 32%, motor 29%, bearing 1%. The three main sources are nearly equal in energy — the worst situation — the total is only 4.2 dB above the largest, and eliminating any one completely lowers the total by at most 1.7–1.9 dB.
In terms of perception: the ear needs 3 dB to notice a clear change, and 10 dB to perceive half the loudness. So a report like 'we swapped in a low-noise fan' with less than 3 dB of magnitude will not be audible on site.
The 76.8 above is the 1 m sound pressure level converted from the equipment surface. The operator station is 3 m away; in free field use 20·lg attenuation:
But a workshop is not a free field. Floor, walls, and equipment shells all reflect; measured attenuation is usually only 3–5 dB per doubling of distance, not 6 dB. So without measured data, the 20·lg result isthe best case, and the actual may be 2–4 dB higher. Optimistic noise calculations get slapped down at acceptance.
Then add background: workshop background 68 dB(A), combined with 67.3 = 70.7 dB(A). At this point stop and look at the difference:
70.7 − 68 = 2.7 dB < 3 dB. Per GB/T 3768, when the difference between total and background sound levels is less than 3 dB, the measurement resultis invalidcannot be used to judge pass/fail. A 3–5 dB difference allows only a 3 dB correction, 6–9 dB a 1 dB correction, and above 10 dB needs no correction.
This is why many sites read '70 first, 74 on retest': the background is too loud and you are not measuring the equipment at all. The correct approach is to stop the machine and measure the background first, or move the unit to an open area / measure at night.
At 1 m, 76.8 exceeds by 1.8 dB; try schemes step by step:
| Scheme | Measure | Total level | Conclusion |
|---|---|---|---|
| A | Low-noise fan only (−6 dB) | 75.3 | Still exceeds limit |
| B | Low-noise fan −6 + gear crowning −3 | 74.2 | Theoretically passes, margin 0.8 < measurement uncertainty ±1.5 |
| C | B + low-noise motor −3 | 72.9 | Margin 2.1 dB, passes |
| D | Fan −10 + gear −3 (motor untouched) | 73.7 | Fan reduced 4 dB more, total level drops only another 0.5 |
Scheme D is the most instructive row: the fan goes from −6 all the way to −10, spending extra on enclosures and silencers, yet the total only falls from 74.2 to 73.7.Because the motor at 71.4 has become the floor; dropping other sources below it is meaningless. At this point either touch the motor or add a full enclosure to the machine.
Look again at single-source sensitivity: lowering any one source by 3 dB drops the total by only 0.7–0.9 dB; lowering the bearing by 3 dB, the totaldoes not move at all. This is the price of equal-energy sources — the noise-reduction budget must be allocated by energy share, not by 'which is easy to change'.
Nine-tenths of noise-calculation errors come from mixing three different quantities. Their units look the same, but the physical meanings are completely different:
| Quantity | Symbol | Meaning | Does it vary with distance | Used for |
|---|---|---|---|---|
| Sound pressure level | Lp | Sound pressure at a point, relative to 20 µPa | Yes, attenuates by 20·lg | Acceptance, occupational health, earplug selection |
| Sound power level | Lw | Total sound energy radiated by the equipment | No, an intrinsic property of the equipment | Maker datasheet, enclosure design |
| A-weighted sound level | dB(A) | Total level corrected by the equal-loudness curve of the human ear | Yes (same as Lp) | All environmental / regulatory indicators |
A datasheet saying 'noise ≤ 72 dB(A)' without stating the measurement point is meaningless in engineering. The industry default is '1 m from the equipment shell, 1.5 m high, semi-free field', but a default is not a contract — the contract must state it clearly.
Conversion between the two (semi-free field, equipment on the ground):
For example, a device with Lw = 85 dB(A) reads Lp = 77 dB(A) at 1 m, 68 dB(A) at 3 m, 57 dB(A) at 10 m. So for the same device, '72 dB at 1 m' and '55 dB at 10 m' may not be contradictory at all.
A-weighting builds a correction network from the inverse of the 40 phon equal-loudness curve: 0 dB at 1 kHz, −3.2 dB at 500 Hz, −8.6 dB at 250 Hz, −26.2 dB at 63 Hz. It means the ear is very insensitive to low frequencies — a 100 dB, 63 Hz low-frequency rumble reads only 74 dB(A) A-weighted, yet its energy is enough to resonate windows and give headaches.
This is why low-frequency equipment (worm-gear reducers, screw pumps, large fans) shows 'measured pass, but unbearable'. To truly assess comfort you must look at the 1/3-octave spectrum, not just the single A-weighted total.
Just remember three common values: Δ = 0 gives +3.0 dB; Δ = 3 gives +1.8 dB; Δ = 10 gives +0.4 dB; Δ ≥ 15 can be ignored. So 'one large, one small' just take the large; 'two equal' add 3 dB.
Parameter description:
| Symbol | Meaning | Unit | Value notes |
|---|---|---|---|
| Li | Sound pressure level of the i-th source | dB(A) | Must be at the same measurement point and same duty |
| Δ | Difference between large and small sources | dB | Used for quick superposition |
| r1, r2 | Measuring-point distance | m | Measured from source center or shell |
| Lw | Sound power level | dB(A) | Maker datasheet value, independent of distance |
| K | Background correction | dB | From table by difference; measurement invalid when difference < 3 |
| z | Pinion tooth count | — | For calculating meshing frequency |
| n | Speed | r/min | — |
| Sound source | Base level | Main variables (coefficients) | Type / accuracy correction |
|---|---|---|---|
| Asynchronous motor | 60 + 2 (cooling) | Power 8·lg(P/1kW); speed 4·lg(n/1500) | Induction 0 / servo −3 / DC +2 / stepper +5 |
| Gear pair | 72 − 1 (lubrication) | Line speed 3·lg(v/5); load per unit face width 2·lg(F/100) | Each accuracy grade difference +1.5, base grade 7 |
| Rolling bearing | 55 | Speed 5·lg(n/1000); bore 2·lg(d/30); load 3·lg(Fr/1000) | Deep-groove ball 0 / angular-contact +2 / cylindrical +5 / taper +7 / self-aligning +9 |
| Fan | 65 | Airflow 10·lg(Q/1000); total pressure 5·lg(P/500) | Centrifugal 0 / mixed-flow +2 / axial +5 |
| Hydraulic pump | 62 | Power 7·lg(P/1kW); pressure 4·lg(p/100) | Screw 0 / centrifugal −2 / vane +3 / gear +5 / plunger +8 |
| L_total − L_background | Correction K | Treatment |
|---|---|---|
| < 3 dB | — | Measurement invalid, must lower background or change site |
| 3~5 dB | −3 dB | Barely usable, result deviation up to ±1.5 dB |
| 6~9 dB | −1 dB | Usable |
| ≥ 10 dB | 0 | No correction needed, ideal |
| Distance | Free field (outdoors / anechoic chamber) | Ordinary workshop (with reflection) | Strong-reverberation workshop |
|---|---|---|---|
| 2 m | −6.0 dB | −3~4 dB | −2~3 dB |
| 3 m | −9.5 dB | −5~6 dB | −3~4 dB |
| 5 m | −14.0 dB | −7~9 dB | −5~7 dB |
| 10 m | −20.0 dB | −10~13 dB | −8~10 dB |
Which column the computed value falls into depends on the room constant R (total room absorption). Small rooms, tiled walls, steel structures with no acoustic treatment take the reverberant column; large plants with suspended absorbers and dense equipment can take the free-field column.
| Equipment | Lp(1m) | Main frequency band | Remarks |
|---|---|---|---|
| Three-phase induction motor 1.1–15 kW | 62~72 dB(A) | Mid-frequency (electromagnetic + fan) | 4-pole, slowly rising with power |
| Single-stage helical reducer | 70~78 dB(A) | Mesh frequency and harmonics | Each accuracy grade differs 1.5 dB |
| Worm-gear reducer | 65~72 dB(A) | Mainly low frequency | A-weighted sounds low, but felt poorly |
| Centrifugal fan 2–10 kW | 75~85 dB(A) | Broadband + blade frequency | Silencer at inlet/outlet is most effective |
| Axial fan (small) | 70~80 dB(A) | Mid-high frequency | 5 dB higher than centrifugal at same parameters |
| Hydraulic pump station | 72~82 dB(A) | Plunger pump has strong single frequency | Pump + motor + relief valve combined |
| Accumulating / slat conveyor line | 65~75 dB(A) | Mid-frequency (sprocket mesh) | Over-tight tensioning rises noticeably |
| Punch press / plate shear | 95~105 dB(A) | Impact broadband | Enclosure + personal protection mandatory |
| Place / standard | Limit | Notes |
|---|---|---|
| Office, design room | 45~55 dB(A) | GB 50118 indoor allowable noise level |
| General production workshop | ≤ 75 dB(A) | Upper limit for clear normal conversation |
| High-noise workshop | 80~85 dB(A) | Must be marked and ear protectors issued |
| GBZ 2.2 occupational exposure (8 h) | 85 dB(A) | 4 h→88,2 h→91,1 h→94 |
| Plant boundary (day / night) | 65 / 55 dB(A) | GB 12348, by functional zone category |
| Wrong practice | Consequence | Correct approach |
|---|---|---|
| Adding or averaging the dB of several sources | In this example averaging gives 68.2, 8.6 dB below the actual 76.8, acceptance will fail | Combine by energy: 10·lg(Σ 10^(Li/10)) |
| Taking the datasheet sound power level as the acceptance value | 1 m and 10 m differ by 20 dB; judging pass/fail in the wrong direction | First convert to the measurement-point sound pressure level, then compare with the limit |
| Using free-field 20·lg for workshop attenuation | Actual attenuation is only 3–5 dB per distance doubling; the calculation is optimistic by 2–4 dB | Take a correction by workshop reverberation, or measure directly |
| Measuring a 70 dB device against 68 dB background | Difference 2.7 dB < 3 dB, data invalid, retest will conflict | Stop the machine to measure background, or change site / measure at night |
| Fixating on small-energy sources like bearings and seals | 1% share; fixing it does not move the total level at all | Rank by energy share; tackle those above 30% first |
| Expecting a quieter machine from a bigger motor | Doubling power adds only 2.4 dB; money spent for no effect | Motor noise is insensitive to power; start with the fan and gear |
| Reporting 'noise reduced' after cutting only one source | Three equal-energy sources — cutting one drops only 1.7–1.9 dB, inaudible | Touch at least two, and require total drop ≥3 dB |
| Not checking mesh frequency against structural natural frequency | 561 Hz lands in the casing resonance band; whine is more piercing than the total level | Compute f = z·n/60 and avoid the natural frequency by ±10% |
| Looking only at the A-weighted total, not the spectrum | Low-frequency equipment 'measured pass, but unbearable' | 1/3-octave spectrum + separate low-frequency assessment; vibration isolation if needed |
Back to this example: motor 71.4, gear 71.8, bearing 57.0, fan 72.6, combined 76.8 dB(A) at 1 m; 3 m operator station 67.3 dB(A), background 68 invalidates the measurement; mesh frequency 561.6 Hz must avoid resonance; finally 'fan −6 + gear −3 + motor −3' gives total 72.9 dB(A), passing. A unit's noise account really comes down to these six numbers.