Knowledge Base › General calculations and examples › How to calculate equipment noise? Example of 5 sound sources combined

How to calculate equipment noise? Example of 5 sound sources combined

🛠️ Baisi Technical Handbook · 500+ standard parts intelligent selection calculations
Covering pneumatic/motor/transmission/reducer/coupling/bearing/hydraulic/pneumatic/screw/worm/spring full series
Avoid 95% of design errors, improve efficiency by 80%
Master 10 years of senior engineer experience in 3 months
Download link: https://pan.baidu.com/s/1bquayZpfas6oYBbG0gp3Gw?pwd=2giv

📖 Coming up next: Vibration isolation design

Noise acceptance is one of the easiest things to fail lately. The contract says operator station within 1 m no higher than 75 dB(A); you check the manuals for ages — motor rated 70, reducer 72, fan 68 — and figure it is fine any way you add it, but on start-up it reads 77 and acceptance stalls.

The problem is in three places: first, decibels cannot be added or averaged; second, the maker rates sound power level while acceptance measures sound pressure level, with distance in between; third, when three sources sound together, none dominates the others.

Below we calculate through a 15 kW powder-mixing unit from scratch, then expand the formulas and value tables.

I. Complete Calculation Example

A powder-mixing unit: 15 kW induction motor directly coupled to a single-stage helical reducer, input speed 1465 r/min, gear pitch-line speed 5.6 m/s, load per unit face width 220 N/mm, accuracy grade 7; input shaft uses a 6210 deep-groove ball bearing (d=50) with radial load 1800 N; the unit has its own axial cooling fan, airflow 2000 m³/h, total pressure 420 Pa. Workshop background noise 68 dB(A). Acceptance: ≤ 75 dB(A) at 1 m.

Step 1 Motor: doubling power only raises 2.4 dB
L_motor = 60 + 8·lg(P) + 4·lg(n/1500) + K_type + 2.0

= 60 + 8×1.176 + 4×(−0.010) + 0 + 2.0 = 71.4 dB(A)

Note the magnitude of the two coefficients: the power term is 8·lg, so doubling power only raises 8×0.301 = 2.4 dB; the speed term is 4·lg, so doubling speed only raises 1.2 dB. That is, swapping 15 kW for 30 kW adds only 2.4 dB; changing the motor from 4-pole to 2-pole (double speed) adds only 1.2 dB. Motor noise is not sensitive to duty parameters — swapping the motor basically cannot solve a noise problem.

Step 2 Gear: what really matters is the accuracy grade
L_gear = 72 + 3·lg(v/5) + 2·lg(F/b÷100) + 1.5·(grade−7) − 1.0

= 72 + 3×0.049 + 2×0.342 + 0 − 1.0 = 71.8 dB(A)

Raising line speed from 5 m/s to 5.6 m/s adds only 0.15 dB; raising load per unit face width from 100 to 220 N/mm adds 0.68 dB. But dropping accuracy from grade 7 to 8 directly +1.5 dB; good crowning/modification reaching grade 6, −1.5 dB。

Many designers reject this conclusion: gear noise is not a mechanics problem but one of accuracy and tooth-surface quality. To shave decibels off the gear, thickening the housing is useless — grinding plus crowning is what works.

By the way, the mesh frequency: f = z₁·n/60 = 23×1465/60 = 561.6 Hz. This frequency must avoid the first natural frequency of the casing and bracket; landing between 540–580 Hz causes resonant whine, which sounds like a sharp whistle and is more annoying than the overall level.

Step 3 Bearing: after calculating you will find it is negligible
L_bearing = 55 + 5·lg(n/1000) + 2·lg(d/30) + 3·lg(Fr/1000) + K_type

= 55 + 5×0.166 + 2×0.222 + 3×0.255 + 0 = 57.0 dB(A)

15 dB below the gear, energy share only 1%. This number is the dividing line for noise reduction — a 1% source, even if completely eliminated, lowers the overall level by only 0.04 dB, i.e. nothing. A rolling bearing, unless pitted, oil-starved, or with a loose cage, is never the main source in normal operation; conversely, if you hear periodic 'clack-clack' impacts on site, that is not a noise issue — the bearing is already failed and you should stop the machine.

Step 4 Fan: doubling flow always raises 3 dB — an iron law
L_fan = 65 + 10·lg(Q/1000) + 5·lg(P_total/500) + K_type

= 65 + 10×0.301 + 5×(−0.076) + 5 = 72.6 dB(A)

The flow term's coefficient is 10·lg, so doubling flow always raises 3.0 dB — no exception, regardless of fan efficiency, blade shape, or maker — it is the result of sound power growing linearly with volumetric flow. So trying to cut flow noise by 'swapping in a good fan' is futile; you can only reduce the flow itself or move the fan farther away.

The type term also matters: at the same flow and pressure, axial is higher than centrifugal by 5 dB, and mixed-flow is 2 dB higher than centrifugal. That 'casually fitted' axial fan on the unit is often the loudest part of the whole machine.

Step 5 Combine: 76.8, not the average 68.2

The four sources' sound pressure levels are 71.4, 71.8, 57.0, 72.6. The arithmetic mean is 68.2, this number is wrong, and wildly wrong— it is lower than any single one of the two main sources, as if conjuring 8.6 dB of noise reduction from nothing.

L_total = 10·lg(10^7.14 + 10^7.18 + 10^5.70 + 10^7.26) = 76.8 dB(A)

Energy shares: fan 38%, gear 32%, motor 29%, bearing 1%. The three main sources are nearly equal in energy — the worst situation — the total is only 4.2 dB above the largest, and eliminating any one completely lowers the total by at most 1.7–1.9 dB.

In terms of perception: the ear needs 3 dB to notice a clear change, and 10 dB to perceive half the loudness. So a report like 'we swapped in a low-noise fan' with less than 3 dB of magnitude will not be audible on site.

Step 6 At the operator station: first apply distance attenuation, then account for background

The 76.8 above is the 1 m sound pressure level converted from the equipment surface. The operator station is 3 m away; in free field use 20·lg attenuation:

Lp(3m) = 76.8 − 20·lg(3/1) = 76.8 − 9.5 = 67.3 dB(A)

But a workshop is not a free field. Floor, walls, and equipment shells all reflect; measured attenuation is usually only 3–5 dB per doubling of distance, not 6 dB. So without measured data, the 20·lg result isthe best case, and the actual may be 2–4 dB higher. Optimistic noise calculations get slapped down at acceptance.

Then add background: workshop background 68 dB(A), combined with 67.3 = 70.7 dB(A). At this point stop and look at the difference:

70.7 − 68 = 2.7 dB < 3 dB. Per GB/T 3768, when the difference between total and background sound levels is less than 3 dB, the measurement resultis invalidcannot be used to judge pass/fail. A 3–5 dB difference allows only a 3 dB correction, 6–9 dB a 1 dB correction, and above 10 dB needs no correction.

This is why many sites read '70 first, 74 on retest': the background is too loud and you are not measuring the equipment at all. The correct approach is to stop the machine and measure the background first, or move the unit to an open area / measure at night.

Step 7 Noise reduction: cutting one is useless, you must cut three

At 1 m, 76.8 exceeds by 1.8 dB; try schemes step by step:

SchemeMeasureTotal levelConclusion
ALow-noise fan only (−6 dB)75.3Still exceeds limit
BLow-noise fan −6 + gear crowning −374.2Theoretically passes, margin 0.8 < measurement uncertainty ±1.5
CB + low-noise motor −372.9Margin 2.1 dB, passes
DFan −10 + gear −3 (motor untouched)73.7Fan reduced 4 dB more, total level drops only another 0.5

Scheme D is the most instructive row: the fan goes from −6 all the way to −10, spending extra on enclosures and silencers, yet the total only falls from 74.2 to 73.7.Because the motor at 71.4 has become the floor; dropping other sources below it is meaningless. At this point either touch the motor or add a full enclosure to the machine.

Look again at single-source sensitivity: lowering any one source by 3 dB drops the total by only 0.7–0.9 dB; lowering the bearing by 3 dB, the totaldoes not move at all. This is the price of equal-energy sources — the noise-reduction budget must be allocated by energy share, not by 'which is easy to change'.

💡 Final result of this example: motor 71.4, gear 71.8, bearing 57.0, fan 72.6 dB(A); after energy combination at 1 m 76.8 dB(A)(not the average 68.2); 3 m operator station 67.3 dB(A); combined with 68 dB(A) background 70.7 dB(A), difference 2.7 dB, measurement invalid, must re-measure background. Mesh frequency 561.6 Hz. For noise reduction use 'fan −6 + gear crowning −3 + low-noise motor −3', total level drops to 72.9 dB(A), margin 2.1 dB, passes.
📐 This algorithm has already been packaged
Baisi Technical Handbook has integrated this calculation module into Batch 3 Professional In-Depth Calculation Module. Enter the operating parameters and it automatically outputs the selection result. No more manual lookups, no more hand calculations, no more experience-based estimates.—— Baisi Technical Handbook download link https://pan.baidu.com/s/1bquayZpfas6oYBbG0gp3Gw?pwd=2giv

II. First, distinguish the three 'decibels'

Nine-tenths of noise-calculation errors come from mixing three different quantities. Their units look the same, but the physical meanings are completely different:

QuantitySymbolMeaningDoes it vary with distanceUsed for
Sound pressure levelLpSound pressure at a point, relative to 20 µPaYes, attenuates by 20·lgAcceptance, occupational health, earplug selection
Sound power levelLwTotal sound energy radiated by the equipmentNo, an intrinsic property of the equipmentMaker datasheet, enclosure design
A-weighted sound leveldB(A)Total level corrected by the equal-loudness curve of the human earYes (same as Lp)All environmental / regulatory indicators

A datasheet saying 'noise ≤ 72 dB(A)' without stating the measurement point is meaningless in engineering. The industry default is '1 m from the equipment shell, 1.5 m high, semi-free field', but a default is not a contract — the contract must state it clearly.

Conversion between the two (semi-free field, equipment on the ground):

Lp = Lw − 20·lg(r) − 8

For example, a device with Lw = 85 dB(A) reads Lp = 77 dB(A) at 1 m, 68 dB(A) at 3 m, 57 dB(A) at 10 m. So for the same device, '72 dB at 1 m' and '55 dB at 10 m' may not be contradictory at all.

What A-weighting actually corrects

A-weighting builds a correction network from the inverse of the 40 phon equal-loudness curve: 0 dB at 1 kHz, −3.2 dB at 500 Hz, −8.6 dB at 250 Hz, −26.2 dB at 63 Hz. It means the ear is very insensitive to low frequencies — a 100 dB, 63 Hz low-frequency rumble reads only 74 dB(A) A-weighted, yet its energy is enough to resonate windows and give headaches.

This is why low-frequency equipment (worm-gear reducers, screw pumps, large fans) shows 'measured pass, but unbearable'. To truly assess comfort you must look at the 1/3-octave spectrum, not just the single A-weighted total.

III. Core Calculation Formulas

1. Multi-source energy combination

L_total = 10·lg( Σ 10^(Li/10) )

2. Two-source combination (quick method)

L_total = L_large + 10·lg(1 + 10^(−Δ/10)) Δ = L_large − L_small

Just remember three common values: Δ = 0 gives +3.0 dB; Δ = 3 gives +1.8 dB; Δ = 10 gives +0.4 dB; Δ ≥ 15 can be ignored. So 'one large, one small' just take the large; 'two equal' add 3 dB.

3. Distance attenuation

L2 = L1 − 20·lg(r2 / r1)

4. Sound power to sound pressure level (semi-free field)

Lp = Lw − 20·lg(r) − 8

5. Background noise correction

L_equipment = L_total − K (K from table by L_total − L_background)

6. Gear mesh frequency

f_mesh = z · n / 60

7. Empirical formulas for the five sources

L = L_base + a·lg(param/base) + b·lg(param/base) + K_type

Parameter description:

SymbolMeaningUnitValue notes
LiSound pressure level of the i-th sourcedB(A)Must be at the same measurement point and same duty
ΔDifference between large and small sourcesdBUsed for quick superposition
r1, r2Measuring-point distancemMeasured from source center or shell
LwSound power leveldB(A)Maker datasheet value, independent of distance
KBackground correctiondBFrom table by difference; measurement invalid when difference < 3
zPinion tooth count—For calculating meshing frequency
nSpeedr/min—

IV. Parameter Selection Reference Tables

1. Coefficients and bases of the five-source empirical formulas

Sound sourceBase levelMain variables (coefficients)Type / accuracy correction
Asynchronous motor60 + 2 (cooling)Power 8·lg(P/1kW); speed 4·lg(n/1500)Induction 0 / servo −3 / DC +2 / stepper +5
Gear pair72 − 1 (lubrication)Line speed 3·lg(v/5); load per unit face width 2·lg(F/100)Each accuracy grade difference +1.5, base grade 7
Rolling bearing55Speed 5·lg(n/1000); bore 2·lg(d/30); load 3·lg(Fr/1000)Deep-groove ball 0 / angular-contact +2 / cylindrical +5 / taper +7 / self-aligning +9
Fan65Airflow 10·lg(Q/1000); total pressure 5·lg(P/500)Centrifugal 0 / mixed-flow +2 / axial +5
Hydraulic pump62Power 7·lg(P/1kW); pressure 4·lg(p/100)Screw 0 / centrifugal −2 / vane +3 / gear +5 / plunger +8
⚠️ The fan pressure-term coefficient 5·lg is a simplified value; by the fan affinity-law specific sound power level, the pressure term should be 20·lg(P). For low-pressure fans (<1 kPa) the 1–2 dB difference is acceptable, but high-pressure fans (above 3 kPa) differ by 6–9 dB and are clearly optimistic. For high-pressure fans, recheck the pressure term with 20·lg.

2. Background noise correction table (GB/T 3768)

L_total − L_backgroundCorrection KTreatment
< 3 dB—Measurement invalid, must lower background or change site
3~5 dB−3 dBBarely usable, result deviation up to ±1.5 dB
6~9 dB−1 dBUsable
≥ 10 dB0No correction needed, ideal

3. Distance attenuation reference (from 1 m)

DistanceFree field (outdoors / anechoic chamber)Ordinary workshop (with reflection)Strong-reverberation workshop
2 m−6.0 dB−3~4 dB−2~3 dB
3 m−9.5 dB−5~6 dB−3~4 dB
5 m−14.0 dB−7~9 dB−5~7 dB
10 m−20.0 dB−10~13 dB−8~10 dB

Which column the computed value falls into depends on the room constant R (total room absorption). Small rooms, tiled walls, steel structures with no acoustic treatment take the reverberant column; large plants with suspended absorbers and dense equipment can take the free-field column.

4. Typical equipment sound pressure level at 1 m

EquipmentLp(1m)Main frequency bandRemarks
Three-phase induction motor 1.1–15 kW62~72 dB(A)Mid-frequency (electromagnetic + fan)4-pole, slowly rising with power
Single-stage helical reducer70~78 dB(A)Mesh frequency and harmonicsEach accuracy grade differs 1.5 dB
Worm-gear reducer65~72 dB(A)Mainly low frequencyA-weighted sounds low, but felt poorly
Centrifugal fan 2–10 kW75~85 dB(A)Broadband + blade frequencySilencer at inlet/outlet is most effective
Axial fan (small)70~80 dB(A)Mid-high frequency5 dB higher than centrifugal at same parameters
Hydraulic pump station72~82 dB(A)Plunger pump has strong single frequencyPump + motor + relief valve combined
Accumulating / slat conveyor line65~75 dB(A)Mid-frequency (sprocket mesh)Over-tight tensioning rises noticeably
Punch press / plate shear95~105 dB(A)Impact broadbandEnclosure + personal protection mandatory

5. Common limits

Place / standardLimitNotes
Office, design room45~55 dB(A)GB 50118 indoor allowable noise level
General production workshop≤ 75 dB(A)Upper limit for clear normal conversation
High-noise workshop80~85 dB(A)Must be marked and ear protectors issued
GBZ 2.2 occupational exposure (8 h)85 dB(A)4 h→88,2 h→91,1 h→94
Plant boundary (day / night)65 / 55 dB(A)GB 12348, by functional zone category

V. Common Errors and Pitfalls

Wrong practiceConsequenceCorrect approach
Adding or averaging the dB of several sourcesIn this example averaging gives 68.2, 8.6 dB below the actual 76.8, acceptance will failCombine by energy: 10·lg(Σ 10^(Li/10))
Taking the datasheet sound power level as the acceptance value1 m and 10 m differ by 20 dB; judging pass/fail in the wrong directionFirst convert to the measurement-point sound pressure level, then compare with the limit
Using free-field 20·lg for workshop attenuationActual attenuation is only 3–5 dB per distance doubling; the calculation is optimistic by 2–4 dBTake a correction by workshop reverberation, or measure directly
Measuring a 70 dB device against 68 dB backgroundDifference 2.7 dB < 3 dB, data invalid, retest will conflictStop the machine to measure background, or change site / measure at night
Fixating on small-energy sources like bearings and seals1% share; fixing it does not move the total level at allRank by energy share; tackle those above 30% first
Expecting a quieter machine from a bigger motorDoubling power adds only 2.4 dB; money spent for no effectMotor noise is insensitive to power; start with the fan and gear
Reporting 'noise reduced' after cutting only one sourceThree equal-energy sources — cutting one drops only 1.7–1.9 dB, inaudibleTouch at least two, and require total drop ≥3 dB
Not checking mesh frequency against structural natural frequency561 Hz lands in the casing resonance band; whine is more piercing than the total levelCompute f = z·n/60 and avoid the natural frequency by ±10%
Looking only at the A-weighted total, not the spectrumLow-frequency equipment 'measured pass, but unbearable'1/3-octave spectrum + separate low-frequency assessment; vibration isolation if needed
🔧 One piece of experience:The core of noise calculation is not 'how many decibels' but 'knowing which part to touch'.Work out the energy shares and the noise-reduction plan emerges by itself: the 38% fan and 32% gear are worth investing in, while the 1% bearing need not be touched at all. Conversely, acting without the shares means the money goes to inaudible places.

Back to this example: motor 71.4, gear 71.8, bearing 57.0, fan 72.6, combined 76.8 dB(A) at 1 m; 3 m operator station 67.3 dB(A), background 68 invalidates the measurement; mesh frequency 561.6 Hz must avoid resonance; finally 'fan −6 + gear −3 + motor −3' gives total 72.9 dB(A), passing. A unit's noise account really comes down to these six numbers.

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL