The core of servo motor selection is inertia matching and torque checking; choosing a motor by power alone is a common misconception. This article gives the two load-referencing methods for linear motion and rotary motion, the recommended inertia ratio range, the acceleration torque formula, and the RMS continuous torque check method, with a worked example built on typical 750W servo parameters. After reading it, you can independently complete the entire motor selection calculation flow.
Servo motors are used where precise position or speed control is required, such as robot joints, CNC axes, and SMT placers. The typical consequences of improper selection: poor inertia matching causes difficult tuning, oscillation, and positioning overshoot; insufficient torque margin causes overload alarms during acceleration or burnout from prolonged overheating.
A common engineering mistake is to select the motor from a rough estimate of "power = force × speed" without doing any inertia referencing or acceleration torque calculation. In reality the rated torque of a servo motor is the continuous running torque; the peak torque during acceleration and deceleration is often 2~3 times the rated value, so the motor maximum torque capability and the RMS torque must be checked. Another misconception is to think that sufficient power is enough, ignoring torque roll-off in the high-speed range.
Inertia referencing for linear motion: Jw = m · (Ph / 2π)²
Inertia referencing for rotary motion: JL = J_load / i² (i is the gear ratio)
Total load inertia: JL_total = Jw + Jc (coupling inertia)
Acceleration torque: Ta = (Jm + JL_total) · α, where α = (2π·n/60) / t_acc
Constant-speed torque: Tf = Ff · Ph / (2π · η)
RMS torque: Trms = [(T1²·t1 + T2²·t2 + T3²·t3) / t_total]^(1/2)
| Parameter | Meaning | Unit |
|---|---|---|
| m | Linear moving mass | kg |
| Ph | Lead | m |
| Jm | Motor rotor inertia | kg·m² |
| Jc | Coupling inertia | kg·m² |
| n | Motor speed | r/min |
| α | Angular acceleration | rad/s² |
| t_acc | Acceleration time | s |
| η | Drive efficiency | — |
| Trms | Equivalent continuous torque | N·m |
| Item | Recommended value | Notes |
|---|---|---|
| Inertia ratio JL/Jm | ≤5 (high response); ≤10 (ordinary positioning) | ≤5 for fast point positioning; ≤10 for smooth conveying |
| Peak torque margin | T_peak ≤ 0.7× motor maximum torque | Keep a 30% margin to cover voltage fluctuation |
| RMS torque margin | Trms ≤ 0.8× rated torque | For long-term continuous operation, do not exceed 80% of rated |
| Speed margin | nmax ≤ 0.9× motor maximum speed | Torque roll-off in the high-speed range requires margin |
Given: Horizontal linear feed axis, m=100 kg, Ph=10 mm, μ=0.003, v=0.5 m/s, t_acc=0.15 s, Jc=5×10^-5 kg·m², η=0.9.
Step 1: Referencing the load inertia.
Jw = 100 × (0.01/2π)² = 2.533×10^-4 kg·m²
JL = 2.533×10^-4 + 0.5×10^-4 = 3.033×10^-4 kg·m²
Step 2: Inertia ratio matching.
Tentatively select a 750W servo, Jm=6×10^-5 kg·m².
Inertia ratio = 3.033×10^-4 / 6×10^-5 = 5.06
For ordinary positioning ≤5~10 is recommended; 5.06 is within a reasonable range ✓
Step 3: Torque calculation.
n = 0.5×60×1000/10 = 3000 r/min
ω = 2π×3000/60 = 314.16 rad/s
α = 314.16/0.15 = 2094 rad/s²
Ff = 0.003×100×9.8 = 2.94 N
Tf = 2.94×0.01/(2π×0.9) = 0.0052 N·m
Ta = (6×10^-5 + 3.033×10^-4) × 2094 = 3.633×10^-4 × 2094 = 0.761 N·m
T_peak = 0.761 + 0.005 = 0.766 N·m
Step 4: Motor torque check.
750W servo: rated torque 2.39 N·m, maximum torque 7.16 N·m.
T_peak=0.766 < 7.16 ✓
RMS torque (1 s cycle: acceleration 0.15 s, constant speed 0.5 s, deceleration 0.15 s, stop 0.2 s):
Trms = [(0.766²×0.15 + 0.005²×0.5 + (-0.756)²×0.15)/1.0]^(1/2)
= [0.1738]^(1/2) ≈ 0.417 N·m
Trms=0.417 < 2.39 N·m ✓
Conclusion: select the 750W servo motor; inertia ratio 5.06, peak 0.766 N·m, RMS 0.417 N·m, all requirements met.
1. When the inertia ratio is too large, add a gearbox first. If the inertia ratio exceeds 10, do not force-select a high-inertia motor; after adding a gearbox the load inertia referenced to the motor shaft is divided by i², which significantly lowers the inertia ratio. Take the gear ratio as √(JL/Jm_target).
2. Vertical loads require a holding torque check. A vertical lifting mechanism slides down under gravity when power is cut, so the motor must have a brake, and the brake holding torque must exceed the load torque produced by gravity.
3. Under frequent start-stop, focus on the RMS check. Peak torque only reflects instantaneous acceleration capability; long-term heating depends on the RMS. On high-cycle loading/unloading equipment, even if the peak stays within limits, an RMS close to the rated value will still cause overheat alarms.
1. Inertia matching decision flowchart: from load type → referencing formula → inertia ratio judgment → whether to add a gearbox.
2. Servo motor torque curve: continuous duty zone, short-time peak zone, and the roll-off curve in the high-speed range.
3. Linear motion referencing diagram: label the worktable, lead, and the referencing path of coupling inertia to the motor shaft.
If you are stuck on the structure, browse complete-line 3D models in the MOULDL Model Library (mouldl model library) — SMT placers, lift-and-transfer units and the like, with parts lists; for data, cross-check against the BST Technical Handbook to be safer.
This article was compiled by Baist Technology (BST) as a reference for mechanical selection.