E41-119 · Motor Selection · Fan Inverter Retrofit · ★★★★
While running at 75Hz the fan suddenly emitted a high-pitched whine and then stopped. Teardown showed the rotor rubbing against the stator core, with the stator bore severely scratched and molten traces on the rotor surface.
The fan's original motor was 4-pole (rated speed 1480rpm), and after the inverter retrofit it routinely ran at 75Hz (2250rpm), a 52% overspeed. The rotor centrifugal stress at 2250rpm is σ_c=ρ×ω²×r²/3=7850×(235.6)²×(0.075)²/3≈8.2MPa, which is below the material limit, but the rotor end banding (impregnated glass tape) is subjected to a centrifugal force F_c=m_end×r_end×ω²=0.5×0.05×(235.6)²≈1388N at overspeed. The banding was designed for a safe speed of 1800rpm (1.2 times rated), so at 2250rpm the banding fractured or loosened and the end windings were thrown out to rub against the stator core. At the same time the bearings heated up under overspeed, the grease was lost, the bearing clearance increased and the rotor sagged, worsening the rub.
1) Overspeed limit for inverter motors: maximum speed ≤1.2 times rated speed
2) At 75Hz the speed is 2250rpm, which already exceeds the limit of 1480×1.2=1776rpm
3) Install an overspeed protection device (speed switch plus PLC monitoring, alarm and shutdown on overspeed)
4) If 75Hz operation is genuinely required, select a 2-pole motor (rated speed 2960rpm×1.2=3552rpm)
5) Or re-balance the motor and reinforce the end banding (allowing a maximum speed of 2500rpm)
FT_12_Motor Selection Systematization