E41-160 · Motor Selection · Centrifugal Pump Motor Alignment · ★★★
The motor was connected to the centrifugal pump through an elastomer coupling, and after three months of running the coupling element shattered while the motor front bearing made abnormal noise. Alignment measurement found a deviation of 0.3mm.
The motor and pump were aligned by eye with a straightedge and no laser aligner. Thermal expansion during running further worsened the misalignment (the motor working temperature rise is 40℃ and the axial elongation is about 0.15mm). The coupling elastomer (polyurethane) is subjected to alternating bending stress under the persistent radial deviation, so tears form inside the elastomer and fragments become trapped between the coupling jaws, causing complete shattering. At the same time the misalignment produces a radial force F_radial=K×δ=2000×0.3=600N acting on the motor bearing, accelerating bearing wear.
1) Motor-to-load alignment requirement: radial ≤0.05mm, angular ≤0.05°
2) Use a laser aligner (accuracy 0.01mm) for alignment adjustment
3) Allow for thermal growth compensation: when aligning cold, leave an offset of 0.08~0.12mm
4) An elastomer coupling cannot compensate large deviations, so use a diaphragm coupling instead
5) Re-check the alignment hot after 24h of running and realign if the deviation exceeds 0.1mm
FT_12_Motor Selection Systematization