E41-169 · Motor Selection · Vibrating Screen Drive Motor · ★★★
Three months after the vibrating screen drive motor started running the vibration value gradually rose from 4mm/s to 15mm/s, fatigue cracks appeared in the motor base and there were signs of loosening at the foundation bolts.
The vibrating screen operates at 16Hz with an 8mm amplitude, so the motor is subjected to a periodic inertia force F=m×a=120×0.008×(2π×16)²≈120×0.008×10106≈9700N. The M16 (grade 8.8) foundation bolts have a preload F_pre=0.7×σ_s×A_s=0.7×660×157≈72.5kN, so each bolt generates a friction force F_fric=F_pre×μ=72.5×0.15≈10.9kN. Four bolts give a total friction force of 43.5kN, greater than 9700N, so in principle they should not loosen. However the sustained alternating load of the vibrating screen causes fretting wear and self-loosening of the bolts (about 5% preload loss per million cycles), and after three months about 2.5×10⁶ cycles the preload has fallen by about 12.5%. In addition the four bolts were not tightened evenly at installation (the torque wrench was not calibrated), so the most heavily loaded bolt loosened first, the load transferred to the remaining bolts and progressive loosening followed.
1) Vibration duty requires anti-loosening washers (a spring washer plus a flat washer combination)
2) Apply thread-locking compound to the bolts (Loctite 242, medium strength)
3) Use a torque wrench and tighten diagonally (M16 torque 200Nm±5%)
4) Check the bolt torque weekly and re-tighten 24h after the first run
5) Rigidly reinforce the mounting base (thicker gusset plates to distribute the vibration force)