High-Temperature Grease Loss on Motor Bearings Causes Dry Running and Burnout (Motor in a High-Temperature Environment)

E41-170 · Motor Selection · Motor in a High-Temperature Environment (beside a Kiln) · ★★★

Problem Symptom

The bearings of the motor installed near the kiln failed every two months, and teardown showed no grease inside the bearing with a worn and shattered cage. Replacing the bearings only repeated the cycle.

Root Cause

The motor was installed 2m from the kiln with an ambient temperature of about 70℃ (thermal radiation). The bearing grease was a general-purpose lithium complex grease (applicable temperature -20~120℃), but the bearing working temperature = ambient 70℃ + the motor's own temperature rise 30℃ = 100℃. At 100℃ the base oil of the lithium complex grease evaporates at about 0.5%/month, so after two months about 40% of the base oil has evaporated and the grease thickens and hardens, losing its lubricating capability. Running without grease the friction coefficient rises from 0.004 to 0.02, increasing the heat generation fivefold → the temperature rises to 130℃ → the grease carbonises → the bearing runs completely dry → the cage shatters. Replacing the bearings repeatedly without solving the high temperature problem simply repeats the failure.

Correct Solution

1) For high-temperature environments (>60℃) use high-temperature grease (such as polyurea or bentonite base)
2) Polyurea grease is applicable from -20~180℃ with a life of 2000h at 150℃
3) Fit a heat shield (10mm ceramic fibre plus a stainless steel reflector plate) to lower the ambient temperature
4) Fit a cooling water jacket on the motor bearing housing (circulating water cooling)
5) Shorten the regreasing interval: normally every 3 months → every month in a high-temperature environment

Checklist

References

FT_12_Motor Selection Systematization

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »