E41-171 · Motor Selection · Servo Motor Encoder Mounting · ★★★
When the servo motor ran at low speed (10rpm) the speed fluctuated, with the encoder feedback showing the speed jumping between 8 and 13rpm. A mechanical inspection of the drive train found nothing abnormal.
The encoder disc was mounted non-concentrically with the motor shaft (eccentricity 0.05mm). At low speed the eccentricity causes a grating signal error Δθ=(e/R)×sin(θ), where the eccentricity e=0.05mm and the disc radius R=20mm. This produces one position error per revolution with an amplitude Δθ=0.05/20×180/π≈0.143°. For a 1024-line encoder (resolution 0.35°) the error is 40% of the resolution. When the servo drive calculates speed from the encoder signal it interprets this periodic position error as speed fluctuation. The lower the speed, the more pronounced the fluctuation, because a position error of fixed amplitude corresponds to a larger speed change at low speed.
1) The encoder mounting eccentricity should be ≤0.01mm (checked with a dial indicator)
2) Use an elastic coupling to connect the encoder (compensating small eccentricity)
3) Select a hollow-shaft encoder (fitted directly onto the motor shaft, with no eccentricity issue)
4) Enable the speed observer or a low-pass filter in the drive
5) Change to a higher resolution encoder (17 bits and above, so the error forms a smaller proportion of the resolution)
FT_12_Motor Selection Systematization