E41-172 · Motor Selection · Vertical Lift Axis Electromagnetic Braking · ★★★★★
The vertical lift axis dropped about 100mm on stopping (position holding error ≤1mm required), and the electromagnetic brake made abnormal noise. The load is a 200kg gearbox.
The electromagnetic brake is a DZM-08 with a static holding torque of 8Nm. The motor speed is n=3000rpm, the reduction ratio i=10 and the load torque is T_load=m×g×r/i=200×9.8×0.05/10=9.8Nm. Since 8Nm < 9.8Nm the braking torque is insufficient, and the gearbox slid down slowly under gravity as it overcame the brake friction. In practice the dynamic friction coefficient of the brake in operation is about 70% of the static coefficient, so the actual braking torque is about 5.6Nm, only 57% of the requirement. In addition the brake has no manual release device, so it cannot be manually released on a power failure (such as when a jam requires manual barring of the motor). The brake response time is about 100ms, during which the motor coasts about 5 revolutions at 3000rpm, corresponding to about 15mm of load travel.
1) Electromagnetic brake selection: T_brake ≥ T_load × SF (SF≥2, and ≥3 for a vertical axis)
2) In this case the braking torque required is ≥9.8×3=29.4Nm → select DZM-30
3) Add a power-off self-locking function (spring-applied brake, automatically clamped on power loss)
4) Add a manual release device (lever or hexagon socket key)
5) Add a mechanical anti-drop device (safety catch or one-way clutch)
FT_12_Motor Selection Systematization