Insufficient airflow due to reverse-mounted motor cooling fan (after repair)

E41-485 · Motor Selection · Motor Fan Reverse Installation · ★★

Problem Description

After reassembly following motor repair, the overheat trip occurred 30 min into operation. Inspection found the cooling fan installed backwards (blades facing the housing side, should face the fan cover side).

Root Cause

The motor cooling fan (axial-flow, diameter Φ280 mm, 6 blades) has a fixed rotation direction by design; the orientation of the blade camber surface determines the airflow direction. After repair the fan was installed backwards, with the blade camber facing the housing (should face the fan cover), so the airflow produced during rotation is opposite to the design (drawing air from housing to cover, whereas normally it should blow from cover to housing). When reversed, airflow Q_rev ≈ 0.3 × Q_norm (about 30% of normal). Cooling airflow drops from 500 m³/h to about 150 m³/h; the convective heat-transfer coefficient h ∝ v^0.8, so a 70% airflow reduction lowers it by about 55%. With insufficient cooling, heat accumulates inside the housing; after 10 min the winding temperature rises from 70℃ to 110℃ (exceeding the B-class insulation limit of 130℃), tripping the thermal relay.

Corrective Solution

① Confirm fan installation direction: blade camber faces the fan cover (produces axial airflow toward the motor)\n② Airflow direction markings (arrow) on fan cover and housing\n③ After repair, manually rotate to check fan rotation direction (matches marking)\n④ After repair, run 30 min no-load and check motor housing temperature (should be 60~70℃)\n⑤ Apply anti-loosening adhesive to fan mounting bolts (prevent fan shift during operation)

Checklist

Reference

FT_12 Systematic Motor Selection