E41-488 · Motor Selection · Motor Lead-Wire Vibration Fracture · ★★★
The lead wire (connection from terminal box to inside the motor) of a vibrating-screen motor (18.5 kW) broke after 8 months of use; the motor then ran single-phase and burned out.
The motor lead wire (stranded copper, 4 mm² cross-section) has a free length of about 50 mm from the terminal to the winding end inside the terminal box. The vibrating screen's vibration acceleration is about 8 g (78.5 m/s²) at 16 Hz. Under continuous vibration the lead wire bears an inertial force F = m × a = 0.02 × 78.5 ≈ 1.6 N (wire mass ~20 g). Bending fatigue occurs at the root of the terminal (stress concentration point), and the copper wire fractures after about 5 × 10⁶ alternating-stress cycles. After the break the motor runs single-phase, current rises to 1.7× rated, and the winding overheats and burns out in about 30 s. The root cause of the lead fracture is: the lead was not fixed inside the terminal box, free length too large (50 mm), so the wire swung freely in vibration and fatigued faster.
① Vibration-duty motor lead length should be ≤20 mm (add a clamp at the terminal root)\n② Secure the wire bundle to the terminal-box inner wall with nylon ties (reduce free swing)\n③ Use a high-flex cable for the lead (fine-stranded, 10× longer bend life)\n④ Fit heat-shrink tubing at the terminal root (adds rigidity, reduces stress concentration)\n⑤ Pot the motor terminal box with insulating compound (epoxy, fully fixes the lead)